Accuracy of patient-specific CT organ doses from Monte Carlo simulations: influence of CT-based voxel models

Author:

Verfaillie GwennyORCID,Rutten JeffORCID,D’Asseler YvesORCID,Bacher KlausORCID

Abstract

AbstractMonte Carlo simulations using patient CT images as input are the gold standard to perform patient-specific dosimetry. However, in standard clinical practice patient’s CT images are limited to the reconstructed CT scan range. In this study, organ dose calculations were performed with ImpactMC for chest and cardiac CT using whole-body and anatomy-specific voxel models to estimate the accuracy of CT organ doses based on the latter model. When the 3D patient model is limited to the CT scan range, CT organ doses from Monte Carlo simulations are the most accurate for organs entirely in the field of view. For these organs only the radiation dose related to scatter from the rest of the body is not incorporated. For organs lying partially outside the field of view organ doses are overestimated by not accounting for the non-irradiated tissue mass. This overestimation depends strongly on the amount of the organ volume located outside the field of view. To get a more accurate estimation of the radiation dose to these organs, the ICRP reference organ masses and densities could form a solution. Except for the breast, good agreement in dose was found for most organs. Voxel models generated from clinical CT examinations do not include the overscan in the z-direction. The availability of whole-body voxel models allowed to study this influence as well. As expected, overscan induces slightly higher organ doses.

Funder

H2020 Euratom

Publisher

Springer Science and Business Media LLC

Reference44 articles.

1. NCRP (2019) Medical radiation exposure of patients in the United States. Report No 184. National Council on Radiation Protection and Measurements. ISBN 9781944888169

2. Damilakis J (2021) CT dosimetry what has been achieved and what remains to be done. Invest Radiol 56:62–68. https://doi.org/10.1097/Rli.0000000000000727

3. Viry A, Bize J, Trueb PR, Ott B, Racine D, Verdun FR, LeCoultre R (2021) Annual exposure of the Swiss population from medical imaging in 2018. Radiat Prot Dosim 195:289–295. https://doi.org/10.1093/rpd/ncab012

4. UNSCEAR (2008) Sources and effects of ionizing radiation. Report to the General Assembly of the United Nations. United Nations, New York. https://digitallibrary.un.org/record/692851

5. HSE (2011) Population dose from CT scanning. Ireland. https://www.radiology.ie/images/uploads/2012/01/ct_population_dose_report.pdf