Examination of conversion method of dose distribution of lung cancer IMRT using fluence reversible calculation function in O-ring type linac and C-type linac

Author:

Rachi ToshiyaORCID,Parshuram Raturi Vijay,Tanaka Yuki,Togo Haruki

Abstract

AbstractGenerally, converting irradiation plans between C-arm linacs (C-linac) when the linac fails is possible without recalculating the dose distribution using a treatment planning system (TPS), because they have similar mechanical structure. However, the O-ring-type linac (O-linac) differs from the C-linac in forming the dose distribution. Therefore, if O-linac breaks down, it is necessary to formulate a treatment plan from scratch. In this study, we investigated a method for converting irradiation from an O-linac to a C-linac. Thirty patients with lung cancer who underwent volumetric-modulated arc therapy with an O-linac were included in this study. The O-linac dose distribution was converted into energy fluence by the function of the TPS. The alternative linac multi-leaf collimator (MLC) was then optimized to achieve energy fluence. The homogeneity index, conformity index, and planning treatment volume (D95%, D2%) of the converted plan were compared with the original plan. For organ at risk (OAR), the dose-volume histograms (DVHs) of the lung, esophagus, heart, and spinal cord were evaluated. Additionally, the shapes of the isodose curves were compared using the Dice similarity coefficient (DSC). There was no significant difference between the target and OARs (p > 0.05). The mean DSCs of 30% to 100% isodose curves of the prescribed dose and the isodose ≥ 105% and ≤ 20%were > 0.8 and < 0.8, respectively. Due to the structural differences of MLC, the dose-volume and generation positions were different in the dose range of ≥ 105% and ≤ 20%; hence, DSCs decreased. However, no statistically significant difference in the DVH was identified for either treatment plan. Based on this result, we propose a simple replanning method for performing MLC fitting after converting the dose to the energy fluence.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Instrumentation,Biomedical Engineering,Biophysics,Radiological and Ultrasound Technology,Biotechnology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3