Abstract
Abstract
Objective
The aim of this study is to assess the effects on procedural, 30-day, and 1‑year all-cause mortality by a newly introduced quality improvement strategy in patients after transcatheter aortic valve replacement (TAVR).
Methods
In October 2015, a coherent set of quality improving interventions with respect to patient geriatric screening, general diagnostic examination and safety of the procedure was implemented at a single centre in the Netherlands. Patients undergoing TAVR in 2013–2018 were included for retrospective analysis. Mortality was assessed in the pre-quality improvement strategy cohort (January 2013 to October 2015; cohort A) and in the post-quality improvement strategy cohort (November 2015 to December 2018; cohort B). Logistic regression analysis was used to estimate the influence of patient and procedural characteristics on the results of the quality improvement strategy in terms of procedural, 30-day, and 1‑year all-cause mortality.
Results
In total, 806 patients were analysed with 274 patients in cohort A and 532 patients in cohort B. After introduction of the quality improvement strategy, procedural (4.4% to 1.3%, p < 0.01), 30-day (8.4% to 2.7%, p < 0.01) and 1‑year (16.4% to 8.5%, p < 0.01) all-cause mortality significantly decreased. Multivariate regression analysis showed that the quality improvement strategy also significantly reduced 30-day (odds ratio [OR] 0.19, 95% confidence interval [CI] 0.09–0.42) and 1‑year (OR 0.38, 95% CI 0.24–0.61) all-cause mortality if corrected for patient characteristics.
Conclusion
Structural meetings on evaluation of outcomes highlight potential areas for improvement and subsequent outcome-based quality improvement initiatives can result in lower procedural, 30-day, and 1‑year all-cause mortality.
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine
Cited by
6 articles.
订阅此论文施引文献