First time description of early lead failure of the Linox Smart lead compared to other contemporary high-voltage leads
Author:
Publisher
Springer Science and Business Media LLC
Subject
Physiology (medical),Cardiology and Cardiovascular Medicine
Link
http://link.springer.com/article/10.1007/s10840-018-0372-9/fulltext.html
Reference20 articles.
1. Providencia R, Kramer DB, Pimenta D, Babu GG, Hatfield LA, Ioannou A, et al. Transvenous implantable cardioverter-defibrillator (ICD) lead performance: a meta-analysis of observational studies. J Am Heart Assoc. 2015;4(11):e002418.
2. Rordorf R, Poggio L, Savastano S, Vicentini A, Petracci B, Chieffo E, et al. Failure of implantable cardioverter-defibrillator leads: a matter of lead size? Heart Rhythm. 2013;10(2):184–90.
3. Good ED, Cakulev I, Orlov MV, Hirsh D, Simeles J, Mohr K, et al. Long-term evaluation of Biotronik Linox and Linox (smart) implantable cardioverter defibrillator leads. J Cardiovasc Electrophysiol. 2016;27(6):735–42.
4. Reichlin T, Kuhne M, Sticherling C. Repetitive inappropriate implantable cardioverter-defibrillator shocks due to insulation failure with externalized conductor cables of a Biotronik Linox SD ICD lead. Europace. 2016;18(5):686.
5. Abi-Saleh B, Refaat MM, Khoury M, Wilkoff B. Conductor externalization of the Biotronik Kentrox internal cardioverter-defibrillator lead: the tip of another iceberg? Heart Rhythm. 2014;11(9):1648–50.
Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Implantable cardioverter defibrillator lead performance: A systematic review and individual patient data Meta-analysis;International Journal of Cardiology;2023-02
2. Performance of an implantable cardioverter‐defibrillator lead family;Journal of Cardiovascular Electrophysiology;2023-01-22
3. Early Experience with the Biotronik Protego ICD Lead;Journal of Clinical Medicine;2022-11-29
4. Recurrent implantable cardioverter-defibrillator shocks due to automatic deactivation of a right ventricular lead noise discrimination algorithm;HeartRhythm Case Reports;2022-10
5. Subcutaneous and Transvenous ICDs: an Update on Contemporary Questions and Controversies;Current Cardiology Reports;2022-05-31