Electrochemical Sensors Based on Manganese and Cobalt Oxide Nanostructures for the Detection of Flutamide and its Derivatives in Real Water Samples

Author:

Ravele Thompho,Hlongwa Ntuthuko W.,Nkambule Thabo T. I.,Gumbi Nozipho N.,Sekhosana Kutloano E.

Abstract

AbstractFlutamide (FLU), bicalutamide (BIC), and hydroxyflutamide (OHF), having a low biodegradability, may cause severe health effects on humans as antiandrogens. In this work, we have developed two electrochemical sensors using manganese oxide (MnO) and Cobalt oxide (CoO) nanostructures (NSs) as electrocatalysts. The GCE modified with MnO is referred to as MnO/GCE and the GCE modified by CoO is referred to as CoO/GCE. The electrochemical behaviours of CoO/GCE and MnO/GCE were examined in ferricyanide solution. It was observed through the employment of cyclic voltammetry that MnO/GCE exhibit better electron transfer than CoO/GCE. The calculated surface coverage values, 1.46 x10−9 mol cm−2 and 5.02 x10−9 mol cm−2 of MnO/GCE and CoO/GCE suggest a multilayer of a metal oxide molecule film at the surfaces of glassy carbon electrodes (GCE). FLU, BIC and OHF were detected at a linear range from 32.01 to 50.00 µM. The limits of detection of FLU, BIC and OHF were 18.5, 13.0 and 78.8 µM at MnO/GCE respectively and 18.8, 18.7 and 18.5 µM at CoO/GCE respectively. Both MnO/GCE and CoO/GCE showed good catalytic stability towards detecting FLU and its derivatives. FLU, BIC and OHF were also detected in the presence of interferents for both electrochemical sensors in phosphate buffer solution. Both MnO/GCE and CoO/GCE confirmed good selectivity without cross interference. Some of the health effects associated with FLU, BIC and OHF are liver damage, prostate inflammation, and methamoglobenia. Although FLU, BIC and OHF are detected in low concentration levels in water bodies, their continuous ingestion is a great concern. As far as we know, MnO and CoO NSs have not been used to electrochemically detect FLU, BIC and OHF. Furthermore, OHF has not been detected electrochemically before and there are only a few studies on the electrochemical detection of BIC. Hence, MnO and CoO NSs are used in this study for the first time for an electrochemical sensor fabrication towards the detection of FLU, BIC and OHF.

Funder

University of South Africa

Publisher

Springer Science and Business Media LLC

Subject

Condensed Matter Physics,General Materials Science,Biochemistry,General Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3