Feasibility and safety of a new endoscopic synthetic sealant nebulizing device over gastric endoscopic submucosal dissections

Author:

Boškoski IvoORCID,Hamanaka Jun,Barbaro Federico,Arena Vincenzo,Mascagni Pietro,Caristo Maria Emiliana,De Siena Martina,Gallo Camilla,Costamagna Guido

Abstract

Abstract Background Endoscopic Submucosal Dissection (ESD) is the treatment of choice of superficial neoplastic gastrointestinal lesions. Delayed bleedings and perforations are still current clinical concerns. Glubran 2 is a synthetic cyanoacrylate-derived glue nowadays already widely used as an effective tissue adhesive. ENDONEB is a novel device thought for enabling the sealant nebulization over a specific targeted surface during laparotomy, laparoscopy, and thoracotomy. The aim of this single-center preclinical animal trial is to evaluate the feasibility and safety of the same nebulization technique during ESD in the perspective that further clinical studies would demonstrate the efficacy of Glubran 2 in preventing post-ESD adverse events. Methods Four live Landrace pigs were enrolled. Two approximately 30-mm-wide gastric ESDs were performed in each pig (experimental ESD and control ESD). About 0.5 mL of Glubran 2 was nebulized on the experimental ESDs. Subjective perception of the feasibility of the Glubran 2 nebulization was reported. Pigs were clinically monitored at follow-up and upper GI endoscopy was performed at 24 and 48 hours, when animals were euthanized to perform a macroscopic and histological analysis of the specimens. Results No peri-procedural adverse events were reported. Glubran 2 nebulization over experimental ESDs showed to be technically easy and time-effective. Clinical and endoscopic animal monitoring was negative at follow-up. At 24 hours, the Glubran 2 film was clearly visible on the eschar of the ESDs and signs of initial hydrolysis were discernable at 48 hours. No signs of peritoneal reaction were observed at the macroscopic examination. Equal transmural inflammation was described at the histological examination of both types of ESDs. Conclusions Safety and feasibility profiles of Glubran 2 nebulizing ENDONEB device over ESD surfaces were excellent. Further evidences and human trials are needed to investigate its effectiveness in ESDs’ eschars sealing and, thus, in delayed micro-perforations and bleedings prevention and treatment.

Funder

Università Cattolica del Sacro Cuore

Publisher

Springer Science and Business Media LLC

Subject

Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3