Comparison of Disposcope endoscope with Macintosh laryngoscope for laryngoscopy

Author:

Gu Ziyu,Zhu Liang,Wu Zhouquan

Abstract

Abstract Purpose Disposcope is a novel fibreoptic intubation device that allows visualization of the glottis without aligning the oral, pharyngeal, and tracheal axes. This device may offer advantages in improving glottis exposure, or reducing hemodynamic disturbance, and minimizing movement of the upper cervical spine (C-spine). In this study, we aimed to evaluate laryngoscopy using Disposcope compared to Macintosh laryngoscope. Methods This study enrolled 60 adult patients (American Society of Anesthesiologists physical status 1 and 2), both male and female, underwent lumbar spine surgery, scheduled for general anesthesia with endotracheal intubation. We compared the Cormack and Lehane grade, hemodynamic response, and the maximal change in the angle between adjacent cervical vertebrae and cumulative upper C-spine movement between Disposcope and Macintosh laryngoscope. A crossover trial design was employed, with half of the patients being exposed to the glottis using the Macintosh laryngoscope first, followed by the Disposcope, and vice versa for the other half. Results The intubation time in the Disposcope group was significantly lower than that in the Macintosh laryngoscope group (P < 0.01). Using the Disposcope resulted in improved views of the glottis (Z = −4.82, P < 0.01). Cormack and Lehane grade I views were achieved with the Disposcope in more patients than the Macintosh laryngoscope (36.7% versus 13.3%, P < 0.01). Grade II views were obtained in 58.3% of patients with the Disposcope, whereas a lower percentage (43.3%) was observed with the Macintosh laryngoscope. The incidence of grade III views was significantly lower with the Disposcope than with the Macintosh laryngoscope (5% versus 33.3%, P < 0.01). Additionally, there was significantly less hemodynamic disturbance (mean arterial pressure and heart rate) with the Disposcope compared to the Macintosh laryngoscope (P < 0.01). Finally, the median cumulative upper C-spine movement was greater with the Macintosh laryngoscope than with the Disposcope (26.9° versus 9.4°, P < 0.01). Conclusions In comparison to the Macintosh laryngoscope, the Disposcope provided improved views of the glottis and resulted in less hemodynamic disturbance and movement of the upper C-spine during laryngoscopy in patients.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3