Defining the role of ab externo Xen gel stent in glaucomatous eyes with prior failed surgical intervention

Author:

To Lillian K.,Dhoot Rupak K.,Chuang Alice Z.,Karimaghaei Sam,Guevara-Abadia Francisco,Shah Ruchi D.,Feldman Robert M.ORCID

Abstract

Abstract Purpose To evaluate the safety and efficacy of Xen45 Gel stent (Xen; Allergan) in eyes that have failed prior surgical intervention, compared to traditional glaucoma drainage device (GDD) or continuous-wave cyclophotocoagulation (CPC). Since this population has low expected success rates with additional surgery, it is vital to compare to standard-of-care surgical options. Methods Retrospective, single-center, case–control study of ab externo transconjunctival Xen shunt in eyes that have previously undergone trabeculectomy and/or GDD surgery. Postoperative data were collected for 18 months. Failure was defined as no light perception, additional glaucoma surgery required, or intraocular pressure (IOP) of < 6 mmHg after 6 weeks postoperatively. Results Eighteen Xen eyes and 36 control eyes matched on both glaucoma type and previous glaucoma surgeries were included. Seventy-two percent had primary open angle glaucoma, 11% uveitic, 6% primary angle closure, 6% pseudoexfoliation, and 6% pigmentary glaucoma. Fifty-six percent of eyes in each group had prior trabeculectomy, 28% of Xen and 31% of control eyes had prior GDD, and 17% of Xen and 14% of control eyes had both. Baseline medicated IOP was lower in the Xen group (21.8 ± 7.2) compared to controls (27.5 ± 9.4, P = 0.043). The cumulative failure rate at year 1 was 17% for Xen and 20% for controls (P = 0.57). Mean survival time was 14.1 (± 1.5) months and 11.4 (± 0.6) months for controls. There was no difference in minor complication rates between groups (P = 0.65), but the Xen group had a significantly lower rate of serious complications (P = 0.043) defined as vision threatening or requiring surgical intervention in the operating room. When censored for additional glaucoma procedures, there were no differences at year 1 in IOP, change in IOP, number of IOP-lowering medications, or number of medications reduced from baseline. Conclusions The Xen shunt provides a reasonable alternative to current standard of care, with a similar failure rate at year 1, with a noninferior IOP reduction compared to GDD and CPC, and a preferred safety profile.

Funder

National Eye Institute

Publisher

Springer Science and Business Media LLC

Subject

Cellular and Molecular Neuroscience,Sensory Systems,Ophthalmology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3