Automated vs. human evaluation of corneal staining

Author:

Kourukmas R.ORCID,Roth M.,Geerling G.

Abstract

Abstract Background and purpose Corneal fluorescein staining is one of the most important diagnostic tests in dry eye disease (DED). Nevertheless, the result of this examination is depending on the grader. So far, there is no method for an automated quantification of corneal staining commercially available. Aim of this study was to develop a software-assisted grading algorithm and to compare it with a group of human graders with variable clinical experience in patients with DED. Methods Fifty images of eyes stained with 2 µl of 2% fluorescein presenting different severity of superficial punctate keratopathy in patients with DED were taken under standardized conditions. An algorithm for detecting and counting superficial punctate keratitis was developed using ImageJ with a training dataset of 20 randomly picked images. Then, the test dataset of 30 images was analyzed (1) by the ImageJ algorithm and (2) by 22 graders, all ophthalmologists with different levels of experience. All graders evaluated the images using the Oxford grading scheme for corneal staining at baseline and after 6–8 weeks. Intrarater agreement was also evaluated by adding a mirrored version of all original images into the set of images during the 2nd grading. Results The count of particles detected by the algorithm correlated significantly (n = 30; p < 0.01) with the estimated true Oxford grade (Sr = 0,91). Overall human graders showed only moderate intrarater agreement (K = 0,426), while software-assisted grading was always the same (K = 1,0). Little difference was found between specialists and non-specialists in terms of intrarater agreement (K = 0,436 specialists; K = 0,417 non-specialists). The highest interrater agreement was seen with 75,6% in the most experienced grader, a cornea specialist with 29 years of experience, and the lowest was seen in a resident with 25,6% who had only 2 years of experience. Conclusion The variance in human grading of corneal staining - if only small - is likely to have only little impact on clinical management and thus seems to be acceptable. While human graders give results sufficient for clinical application, software-assisted grading of corneal staining ensures higher consistency and thus is preferrable for re-evaluating patients, e.g., in clinical trials.

Funder

Heinrich-Heine-Universität Düsseldorf

Publisher

Springer Science and Business Media LLC

Subject

Cellular and Molecular Neuroscience,Sensory Systems,Ophthalmology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3