Abstract
Abstract
Purpose
To compare the results of retinal venous pressure (RVP) measurement performed with contact lens dynamometry (CLD) and with the new IOPstim.
Methods
In this cross-sectional study, we included 36 patients with primary open angle glaucoma with a median age (Q25; Q75) of 74 (64; 77) years (m/f = 18/18), baseline intraocular pressure (IOP): 13.9 (12.2; 15.1) mmHg. Median mean defect: − 5.8 (− 11.9; − 2.6) db. Principle of the IOPstim: an empty balloon with a diameter of 8 mm is positioned on the eye, laterally of the limbus. Under observation of the central retinal vein (CRV), the examiner inflates the balloon. As soon as the CRV starts pulsation, the inflation is stopped and the IOP is measured, equaling the RVP at this moment. In the CLD, the pulsation of the CRV is observed with a contact lens. The RVP is calculated from the attachment force applied when pulsation appears.
Course of examinations
Three single measurements of RVP in quick succession with both methods. The sequence of the two methods was randomized. The means of the three RVP measurements were compared.
Results
Pressures in mmHg. RVP: IOPstim: 19.4 ± 5.4 (mean ± SD), CLD: 20.3 ± 5.9. Range of three single measurements: IOPstim: 2.9 ± 1.5, CLD: 2.2 ± 1.1. The differences were RVPIOPstim − RVPCLD = − 0.94 ± 1.15, and approximately normally distributed. Bland–Altman analysis: only one data point was 0.5 mmHg higher than the upper line of agreement. The confidence interval of this line was 0.65 mmHg. Concordance correlation coefficient according to Lin (CCC): 0.96. Intraclass correlation coefficient: both methods, 0.94.
Conclusion
In both methods, the range of the single measurements may be taken as a sign of good reliability, the CCC of 0.96 as a sign of a very good agreement. At the mean, the IOPstim RVP values were 1 mmHg lower than those obtained with the CLD. This difference may be due to the different directions of the prevailing force vectors induced by the instruments. The IOPstim seems applicable in glaucoma diagnostics.
Funder
Universitätsklinikum Carl Gustav Carus Dresden an der Technischen Universität Dresden
Publisher
Springer Science and Business Media LLC