Real-time colorectal polyp detection using a novel computer-aided detection system (CADe): a feasibility study

Author:

Soons E.,Rath T.,Hazewinkel Y.,van Dop W. A.,Esposito D.,Testoni P. A.,Siersema P. D.

Abstract

Abstract Background and aims Colonoscopy aims to early detect and remove precancerous colorectal polyps, thereby preventing development of colorectal cancer (CRC). Recently, computer-aided detection (CADe) systems have been developed to assist endoscopists in polyp detection during colonoscopy. The aim of this study was to investigate feasibility and safety of a novel CADe system during real-time colonoscopy in three European tertiary referral centers. Methods Ninety patients undergoing colonoscopy assisted by a real-time CADe system (DISCOVERY; Pentax Medical, Tokyo, Japan) were prospectively included. The CADe system was turned on only at withdrawal, and its output was displayed on secondary monitor. To study feasibility, inspection time, polyp detection rate (PDR), adenoma detection rate (ADR), sessile serrated lesion (SSL) detection rate (SDR), and the number of false positives were recorded. To study safety, (severe) adverse events ((S)AEs) were collected. Additionally, user friendliness was rated from 1 (worst) to 10 (best) by endoscopists. Results Mean inspection time was 10.8 ± 4.3 min, while PDR was 55.6%, ADR 28.9%, and SDR 11.1%. The CADe system users estimated that < 20 false positives occurred in 81 colonoscopy procedures (90%). No (S)AEs related to the CADe system were observed during the 30-day follow-up period. User friendliness was rated as good, with a median score of 8/10. Conclusion Colonoscopy with this novel CADe system in a real-time setting was feasible and safe. Although PDR and SDR were high compared to previous studies with other CADe systems, future randomized controlled trials are needed to confirm these detection rates. The high SDR is of particular interest since interval CRC has been suggested to develop frequently through the serrated neoplasia pathway. Clinical Trial Registration The study was registered in the Dutch Trial Register (reference number: NL8788).

Publisher

Springer Science and Business Media LLC

Subject

Gastroenterology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3