Abstract
AbstractThe present study evaluated the contamination by monoaromatic hydrocarbons (BTEX: benzene, toluene, ethylbenzene, and xylene) of the subsurface of gas stations and adjacent residences in the Amazonian town of Bragança, in northern Brazil. We combined the ground penetrating radar (GPR) geophysical tool, to detect possible plumes of contamination by BTEX, with gas chromatography (GC) and mass spectrometry (MS), which were used to diagnose the presence of BTEX in water samples obtained from boreholes located within the study area. The GPR identified low-amplitude reflections in the vadose zone of two gas stations, whose attenuation near the surface was due to the low permittivity recorded in the radargrams, which may have been caused by the reduced permittivity of the hydrocarbons (gas vapor) in comparison with water. The GC–MS identified benzene, toluene, ethylbenzene and/or xylene in 13 water samples (19.7% of the samples collected). Only three of the samples contained two contaminants, invariably toluene and xylene, whereas all the others contained only a single BTEX. Toluene and xylene were the BTEX compounds found most frequently in the samples. However, none of the samples collected in the study exceeded the threshold established by Brazilian legislation for BTEXs in drinking water. The integrated application of GPR and CG-MS produced satisfactory results for the diagnosis of the contamination of the subsurface of the gas stations surveyed in the present study.
Funder
Pró-Reitoria de Pesquisa e Pós-Graduação, Universidade Federal do Pará
Fundação Amazônia Paraense de Amparo à Pesquisa
Publisher
Springer Science and Business Media LLC
Subject
Earth-Surface Processes,Geology,Pollution,Soil Science,Water Science and Technology,Environmental Chemistry,Global and Planetary Change
Reference74 articles.
1. Aal GZAD, Werkema D Jr, Sauck WA, Atekwana EA (2001) Geophysical investigation of vadose zone conductivity anomalies at a former refinery site, Kalamazoo, MI. Symp Appl Geophys Eng Environ Prob. https://doi.org/10.4133/1.2922968
2. Abbas M, Jardani A, Machour N, Dupont J-P (2018) Geophysical and geochemical characterisation of a site impacted by hydrocarbon contamination undergoing biodegradation. Near Surface Geophysics 16:176–192. https://doi.org/10.3997/1873-0604.2017061
3. Aktürk O, Doyuran V (2015) Integration of electrical resistivity imaging (ERI) and ground penetrating radar (GPR) methods to identify soil profile around Necatibey Subway Station, Ankara, Turkey. Environ Earth Sci 74:2197–2208. https://doi.org/10.1007/s12665-015-4211-3
4. Allahabady A, Yousefi Z, Tahamtan RAM (2022) Sharif ZP (2022) Measurement of BTEX (benzene, toluene, ethylbenzene and xylene) concentration at gas stations. Environ Health Eng Manag J 9:23–31. https://doi.org/10.34172/EHEM.2022.04
5. ANA (2011) Agência Nacional de Águas-Ministério do Meio Ambiente. Companhia Ambiental do Estado de São Paulo. Guia nacional de coleta e preservação de amostras: água, sedimento, comunidades aquáticas e efluentes líquidas. Brasília, 326 p. Available online: . Accessed on 06 February 2021
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献