Flash-kinetics as a complementary analytical tool in PAM fluorimetry

Author:

Klughammer Christof,Schlosser Friedemann,Schreiber UlrichORCID

Abstract

AbstractA new measuring system based on the already existing Multi-Color-PAM Fluorimeter (Schreiber et al. in Photosynth Res 113:127–144, 2012) was developed that in addition to standard PAM measurements enables pump-and-probe flash measurements and allows simultaneous measurements of the changes in chlorophyll fluorescence yield (F) during application of saturating flashes (ST). A high-power Chip-on-Board LED array provides ST flashes with close to rectangular profiles at wide ranges of widths (0.5 µs to 5 ms), intensities (1.3 mmol to 1.3 mol 440 nm quanta m−2 s−1) and highly flexible repetition times. Using a dedicated rising-edge profile correction, sub-µs time resolution is obtained for assessment of initial fluorescence and rise kinetics. At maximal to moderate flash intensities the flash-kinetics (changes of F during course of ST, STK) are strongly affected by ‘High Intensity Quenching’ (HIQ), consisting of Car-triplet quenching, TQ, and donor-side-dependent quenching, DQ. The contribution of TQ is estimated by application of a second ST after 20 µs dark-time. Upon application of flash trains (ST sequences with defined repetition times) typical period-4 oscillations in dark fluorescence yield (F0) and ST-induced fluorescence yield, FmST, are obtained which can be measured in vivo both with suspensions and from the surface of leaves. Examples of application with dilute suspensions of Chlorella and an intact dandelion leaf are presented. It is shown that weak far-red light (730–740 nm) advances the S-state distribution of the water-splitting system by one step, resulting in substantial lowering of FmST and also of the I1-level in the polyphasic rise of fluorescence yield induced by a multiple-turnover flash (MT). Based on comparative measurements of STK and the polyphasic rise kinetics with the same Chlorella sample, it is concluded that the generally observed lower values of maximal fluorescence yields using ST-protocols compared to MT-protocols are due to a higher extent of HIQ (mainly DQ) and the contribution of variable PSI fluorescence to FmST.

Publisher

Springer Science and Business Media LLC

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. LETTER TO THE EDITOR;Photosynthetica;2024-08-23

2. LETTER TO THE EDITOR;Photosynthetica;2024-06-27

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3