Functional outcome and quality of life following resection of the proximal humerus performed for musculoskeletal tumors and reconstruction done by four different methods

Author:

Antal I.,Szőke G.,Szendrői M.,Szalay K.,Perlaky T.,Kiss J.,Skaliczki G.

Abstract

Abstract Introduction The proximal humerus is a frequent site for both primary and secondary bone tumors. Several options are currently available to reconstruct the resected humerus, but there is no consensus regarding optimal reconstruction. The aim of this retrospective study was to compare the functional outcome, complications and patient compliance following four different types of reconstructive techniques. Material and methods The authors performed 90 proximal humerus resections due to primary and secondary bone tumors over the past 21 years. Four different procedures were performed for reconstruction following the resection: fibula autograft transplantation, osteoarticular allograft implantation, modular tumor endoprosthesis (hemiarthroplasty) and reconstruction of the defect with a reverse shoulder prosthesis-allograft composite. A retrospective analysis of the complications and patient’s physical status was performed. Functional outcome and life quality was evaluated by using the MSTS and SF-36 scores. Results The best range of motion was observed following arthroplasty with a reverse shoulder prosthesis-homograft composite followed by a fibula autograft reconstruction. Revision surgery was required due to major complications most frequently in the osteoarticular allograft group, followed by the reverse shoulder prosthesis-allograft composite group, the autologous fibula transplantation group; the tumor endoprosthesis hemiarthroplasty group had superior results regarding revision surgery (40, 25, 24 and 14% respectively). MSTS was 84% on average for the reverse shoulder prosthesis-allograft composite group, 70% for the autologous fibula group, 67% for the anatomical hemiarthroplasty group and 64% for the osteoartricular allograft group. Using the SF-36 questionnaire for assessment no significant differences were found between the four groups regarding quality of life. Discussion Based on the results of our study the best functional performance (range of motion and patient compliance) was achieved in the a reverse prosthesis-allograft combination group—in cases where the axillary nerve could be spared. The use of an osteoarticular allograft resulted in unsatisfying functional results and high complication rates, therefore we do not recommend it as a reconstructive method following resection of the proximal humerus due to either primary or metastatic bone tumors. Young patients who have good life expectancy but a small humerus or intramedullar cavity reconstruction by implantation of a fibula autograft is a good option. For patients with a poor prognosis (i.g. bone metastases) or in cases where the axillary nerve must be sacrificed, hemiarthroplasty using a tumor endoprosthesis was found to have acceptable results with a low complication rate. According to the MSTS and SF-36 functional scoring systems patients compliance was nearly identical following all four types of reconstruction techniques; the underlying cause may be the complexity of the shoulder girdle. However, we recommend the implantation of a reverse shoulder prosthesis-allograft whenever indication is appropriate, as it has been demonstrated to provide excellent functional outcomes, especially in young adults.

Funder

Semmelweis University

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3