Abstract
Abstract
Purpose
Electrocardiogram (ECG) signals collected from wearable devices are easily corrupted with surrounding noise and artefacts, where the signal-to-noise ratio (SNR) of wearable ECG signals is significantly lower than that from hospital ECG machines. To meet the requirements for monitoring heart disease via wearable devices, eliminating useless or poor-quality ECG signals (e.g., lead-falls and low SNRs) can be solved by signal quality assessment algorithms.
Methods
To compensate for the deficiency of the existing ECG quality assessment system, a wearable ECG signal dataset from heart disease patients collected by Lenovo H3 devices was constructed. Then, this paper compares the performance of three machine learning algorithms, i.e., the traditional support vector machine (SVM), least-squares SVM (LS-SVM) and long short-term memory (LSTM) algorithms. Different non-morphological signal quality indices (i.e., the approximate entropy (ApEn), sample entropy (SaEn), fuzzy measure entropy (FMEn), Hurst exponent (HE), kurtosis (K) and power spectral density (PSD) features) extracted from the original ECG signals are fed into the three algorithms as input.
Results
The true positive rate, true negative rate, sensitivity and accuracy are used to evaluate the performance of each method, and the LSTM algorithm achieves the best results on these metrics (97.14%, 86.8%, 97.46% and 95.47%, respectively).
Conclusions
Among the three algorithms, the LSTM-based quality assessment method is the most suitable for the signals collected by the Lenovo H3 devices. The results also show that the combination of statistical features can effectively evaluate the quality of ECG signals.
Funder
National Key Research and Development Program of China
Jiangsu Provincial Key Research and Development Program
National Natural Science Foundation of China
Zhejiang Provincial Natural Science Foundation of China
Publisher
Springer Science and Business Media LLC
Subject
Biomedical Engineering,General Medicine
Reference30 articles.
1. Liu, C., Yang, M., Di, J., Xing, Y., Li, Y., & Li, J. (2019). Wearable ECG: History, key technologies and future challenges. Chinese Journal of Biomedical Engineering, 38(6), 641–652.
2. Fouassier, D., Roy, X., Blanchard, A., & Hulot, J. S. (2020). Assessment of signal quality measured with a smart 12-lead ECG acquisition T-shirt. Annals of Noninvasive Electrocardiology, 25(1), e12682.
3. Li, Q., & Clifford, G. D. (2012). Signal quality and data fusion for false alarm reduction in the intensive care unit. Journal of Electrocardiology, 45(6), 596–603.
4. Redmond, S. J., Xie, Y., Chang, D., Basilakis, J., & Lovell, N. H. (2012). Electrocardiogram signal quality measures for unsupervised telehealth environments. Physiological Measurement, 33(9), 1517–1533.
5. Naseri, H., & Homaeinezhad, M. (2014). Electrocardiogram signal quality assessment using an artificially reconstructed target lead. Computer methods in Biomechanics and Biomedical Engineering, 18(10), 1126–1141.
Cited by
19 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献