Effects of Electrode Position Targeting in Noninvasive Electromyography Technologies for Finger and Hand Movement Prediction
-
Published:2023-09-26
Issue:5
Volume:43
Page:603-611
-
ISSN:1609-0985
-
Container-title:Journal of Medical and Biological Engineering
-
language:en
-
Short-container-title:J. Med. Biol. Eng.
Author:
Wang Michelle, Khundrakpam Budhachandra, Vaughan ThomasORCID
Abstract
Abstract
Purpose
Stroke patients may need to undergo rehabilitation therapy to improve their mobility. Electromyography (EMG) can be used to improve the effectiveness of at-home therapy programs, as it can assess recovery progress in the absence of a health professional. In particular, EMG armbands have the advantage of being easy to use compared to other EMG technologies, which could allow patients to complete therapy programs without external assistance. However, it is unclear whether there are drawbacks associated with the fixed electrode placement imposed by current armband designs. This study compared the hand gesture prediction capabilities of an off-the-shelf EMG armband with fixed electrode placement and an EMG setup with flexible electrode positioning.
Methods
Ten able-bodied participants performed a series of hand and finger gestures with their dominant hand, once with an EMG armband (Untargeted condition) and once with electrodes deliberately placed on specific muscles (Targeted condition). EMG features were extracted from overlapping sliding windows and were used to (1) classify the gestures and (2) predict finger joint positions as measured by a robotic hand exoskeleton.
Results
For the classification task, a logistic regression model performed significantly better ($$p < 0.001$$
p
<
0.001
) for the Targeted condition ($$55.8\% \pm 10.1\%$$
55.8
%
±
10.1
%
) compared to the Untargeted condition ($$47.9\% \pm 11.6\%$$
47.9
%
±
11.6
%
). For the regression task, a k-nearest neighbours model obtained significantly lower ($$p = 0.007$$
p
=
0.007
) mean RMSE values for the Targeted condition ($$0.260 \pm 0.037$$
0.260
±
0.037
) compared to the Untargeted condition ($$0.270 \pm 0.043$$
0.270
±
0.043
).
Conclusion
We observed a trade-off between predictive accuracy and ease-of-use of the EMG devices used in this study. It is important to consider such a trade-off when developing clinical applications such as at-home stroke rehabilitation therapy programs.
Funder
NSERC-CREATE Fonds de recherche du Québec – Nature et technologies National Research Council Canada
Publisher
Springer Science and Business Media LLC
Subject
Biomedical Engineering,General Medicine
Reference36 articles.
1. Feigin, V. L., Stark, B. A., Johnson, C. O., Roth, G. A., Bisignano, C., Abady, G. G., Abbasifard, M., Abbasi-Kangevari, M., Abd-Allah, F., Abedi, V. & Abualhasan, A. (2021). Global, regional, and national burden of stroke and its risk factors, 1990–2019: a systematic analysis for the Global Burden of Disease Study 2019. The Lancet Neurology, 20, 795–820. 2. Tsao, C. W., Aday, A. W., Almarzooq, Z. I., Alonso, A., Beaton, A. Z., Bittencourt, M. S., Boehme, A. K., Buxton, A. E., Carson, A. P., Commodore-Mensah, Y. & Elkind, M. S. (2022). Heart disease and stroke statistics-2022 update: A report from the American Heart Association. Circulation. https://doi.org/10.1161/CIR.0000000000001052 3. Broeks, J. G., Lankhorst, G. J., Rumping, K., & Prevo, A. J. H. (1999). The long-term outcome of arm function after stroke: results of a follow-up study. Disability and Rehabilitation, 21, 357–364. https://doi.org/10.1080/096382899297459 4. Raghavan, P. (2007). The nature of hand motor impairment after stroke and its treatment. Current Treatment Options in Cardiovascular Medicine, 9, 221–228. https://doi.org/10.1007/s11936-007-0016-3 5. Welmer, A. K., Holmqvist, L. W., & Sommerfeld, D. K. (2008). Limited fine hand use after stroke and its association with other disabilities. Journal of Rehabilitation Medicine, 40, 603–608.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|