Abstract
AbstractIn the last decades, recent earthquakes have further highlighted the high vulnerability of non-structural components. Post-earthquake damage due to building envelope, equipment and building contents can lead to substantial economic losses in terms of repair costs and daily activity interruption (downtime). Moreover, non-structural damage can represent a life-safety threat for both occupants and pedestrians. These considerations confirm the crucial need for developing low-damage systems for either structural or non-structural elements. This paper aims to assess the seismic performance of glazed facade systems, widely adopted in modern buildings, focusing on point fixed glass facade systems (PFGFSs), also referred to as “spider glazing”. In this work, a numerical investigation is developed to study the seismic performance of such systems at both local-connection level through a 3D FEM in ABAQUS as well as at global system level through a simplified lumped plasticity model in SAP 2000 to assess the overall in-plane capacity of the facade. Based on the local connection and global facade system behavior, a novel low-damage connection system is herein proposed, and a parametric study is carried out on the key parameters influencing the facade capacity. The benefits of implementing low-damage connection details are highlighted by an increase of the in-plane capacity of the facade system when compared to a traditional solution. To further investigate the potential of the proposed low-damage details in preserving the integrity of the facade system itself, non-linear time history analyses have been carried out on a case-study building equipped with the innovative PFGFSs.
Funder
Università degli Studi di Roma La Sapienza
Publisher
Springer Science and Business Media LLC
Subject
Geophysics,Geotechnical Engineering and Engineering Geology,Building and Construction,Civil and Structural Engineering
Reference52 articles.
1. ABAQUS Inc. (2011) Abaqus FEA. Providence
2. Aiello C, Caterino N, Bonati A, Occhiuzzi A (2019) The role of details for seismic performance of a full scale glass façade. In: 4th international workshop on the seismic performance of non-structural elements (SPONSE), Pavia
3. Aiello C, Caterino N, Maddaloni G, Bonati A, Franco A, Occhiuzzi A (2018) Experimental and numerical investigation of cyclic response of a glass curtain wall for seismic performance assessment. Constr Build Mater 187:596–609. https://doi.org/10.1016/j.conbuildmat.2018.07.237
4. American Society of Civil Engineers ASCE (2010) ASCE/SEI-7-10 minimum design loads for buildings and other structures, Virginia
5. Applied Technology Council (1996) Seismic evaluation and retrofit of concrete buildings. Volume 1 Technical Report ATC 40, Redwood City