Abstract
Abstract
Purpose
In this retrospective, observational study we aim to compare the outcomes of the RFA treatment of benign thyroid nodules, carried out respectively with the standard fixed-needle approach (FTN) and the adjustable-tip needle technique (ATN), considered a more tailored, quicker and easier technical approach.
Methods
We enrolled 36 patients who underwent RFA treatment of symptomatic, benign, thyroid nodule, 18 with the ATN and 18 with the FTN approach, respectively. Data about absolute volume reduction, volume reduction rate (VRR) and success rate (defined as VRR ≥ 50%), after 1, 3 and 6 months of follow-up were compared.
Results
Our study suggested no substantial difference between the approaches, up to 6 months of follow-up, both in terms of absolute reduction (p = 0.27) and VRR (p = 0.14). These results were confirmed when the success rates, both in terms of 50%-reduction (p = 0.12) and absolute reduction (p = 0.42), was considered. Only at the 6-month evaluation, the FTN procedure showed a better success rate, yet without statistical significance (88.9% vs. 61.1%, p = 0.12). No difference emerged both in terms of patients’ satisfaction and safety.
Conclusion
Our small experience suggested no substantial difference between ATN and FTN, in terms of outcomes. On the other hand, ATN was considered to be more straightforward and could consequently allow for a shorter operator learning curve.
Funder
Università degli Studi di Torino
Publisher