Fluorescence-guided detection of pituitary neuroendocrine tumor (PitNET) tissue during endoscopic transsphenoidal surgery available agents, their potential, and technical aspects

Author:

Vergeer Rob AORCID,Theunissen Robin E PORCID,van Elk TheodoraORCID,Schmidt Iris,Postma Mark RORCID,Tamasi KatalinORCID,van Dijk J Marc CORCID,Kuijlen Jos M AORCID

Abstract

AbstractDifferentiation of pituitary neuroendocrine tumor (PitNET) tissue from surrounding normal tissue during surgery is challenging. A number of fluorescent agents is available for visualization of tissue discrepancy, with the potential of improving total tumor resection. This review evaluates the availability, clinical and technical applicability of the various fluorescent agents within the field of pituitary surgery. According to PRISMA guidelines, a systematic review was performed to identify reports describing results of in vivo application of fluorescent agents. In this review, 15 publications were included. Sodium Fluorescein (FNa) was considered in two studies. The first study reported noticeable fluorescence in adenoma tissue, the second demonstrated the strongest fluorescence in non-functioning pituitary adenomas. 5-Aminolevulinic acid (5-ALA) was investigated in three studies. One study compared laser-based optical biopsy system (OBS) with photo-diagnostic filter (PD) and found that the OBS was able to detect all microadenomas, even when MRI was negative. The second study retrospectively analyzed twelve pituitary adenomas and found only one positive for fluorescence. The third investigated fifteen pituitary adenomas of which one displayed vague fluorescence. Indocyanine green (ICG) was researched in four studies with variable results. Second-Window ICG yielded no significant difference between functioning and non-functioning adenomas in one study, while a second study displayed 4 times higher fluorescence in tumor tissue than in normal tissue. In three studies, OTL38 showed potential in non-functioning pituitary adenomas. At present, evidence for fluorescent agents to benefit total resection of PitNETs is lacking. OTL38 can potentially serve as a selective fluorescent agent in non-functioning pituitary adenomas in the near future.

Publisher

Springer Science and Business Media LLC

Subject

Endocrinology,Endocrinology, Diabetes and Metabolism

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3