Abstract
Abstract
Background
Optimal fluid balance for peritoneal dialysis (PD) patients requires both water and sodium removal. Previous studies have variously reported that continuous ambulatory peritoneal dialysis (CAPD) removes more or equivalent amounts of sodium than automated PD (APD) cyclers. We therefore wished to determine peritoneal dialysate losses with different PD treatments.
Methods
Peritoneal and urinary sodium losses were measured in 24-h collections of urine and PD effluent in patients attending for their first assessment of peritoneal membrane function. We adjusted fluid and sodium losses for CAPD patients for the flush before fill technique.
Results
We reviewed the results from 659 patients, mean age 57 ± 16 years, 56.3% male, 38.9% diabetic, 24.0% treated by CAPD, 22.5% by APD and 53.5% APD with a day-time exchange, with icodextrin prescribed to 72.8% and 22.7 g/L glucose to 31.7%. Ultrafiltration was greatest for CAPD 650 (300–1100) vs 337 (103–598) APD p < 0.001, vs 474 (171–830) mL/day for APD with a day exchange. CAPD removed most sodium 79 (33–132) vs 23 (− 2 to 51) APD p < 0.001, and 51 (9–91) for APD with a day exchange, and after adjustment for the CAPD flush before fill 57 (20–113), p < 0.001 vs APD. APD patients with a day exchanged used more hypertonic glucose dialysates [0 (0–5) vs CAPD 0 (0–1) L], p < 0.001.
Conclusion
CAPD provides greater ultrafiltration and sodium removal than APD cyclers, even after adjusting for the flush-before fill, despite greater hypertonic usage by APD cyclers. Ultrafiltration volume and sodium removal were similar between CAPD and APD with a day fill.
Publisher
Springer Science and Business Media LLC
Reference29 articles.
1. Davenport A (2009) Peritonitis remains the major clinical complication of peritoneal dialysis: the London, UK, peritonitis audit 2002–2003. Perit Dial Int 29(3):297–302
2. Brown EA, Davies SJ, Rutherford P, Meeus F, Borras M, Riegel W, Divino Filho JC, Vonesh E, van Bree M, EAPOS Group (2003) Survival of functionally anuric patients on automated peritoneal dialysis: the European APD Outcome Study. J Am Soc Nephrol 14(11):2948–2957
3. Johnson DW, Hawley CM, McDonald SP, Brown FG, Rosman JB, Wiggins KJ, Bannister KM, Badve SV (2010) Superior survival of high transporters treated with automated versus continuous ambulatory peritoneal dialysis. Nephrol Dial Transplant 25(6):1973–1979
4. Inal S, Erten Y, Okyay GU, Ataş N, Oneç K, Yayla C, Tekbudak MY, Sahin G, Tavil Y, Sindel S (2014) Association between bioimpedance analysis parameters and left ventricular hypertrophy in peritoneal dialysis patients. Int Urol Nephrol 46(9):1851–1856
5. Findlay M, MacIsaac R, MacLeod MJ, Metcalfe W, Traynor JP, Dawson J, Mark PB (2018) Renal replacement modality and stroke risk in end-stage renal disease—a national registry study. Nephrol Dial Transplant 33(9):1564–1571
Cited by
11 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献