Abstract
Abstract
Purpose
We compared two techniques for thoracic apical derotation; one using conventional reduction screws (Single-Innie–SI) and one requiring special derotation screws that can be converted to monoaxial screws to enhance dorotation (Dual-Innie–DI) for coronal and sagittal correction and.
Methods
A total of 200 patients with thoracic AIS have been included. In the SI-Group (n = 127) the convex rod was applied first. Vertebral derotation was done by translation to the concave rod with the convex rod being in place and center of rotation (COR). In the DI-Group (n = 73) correction started with translation on the concave side as well but now followed by derotation around the concave rod using the DI-mechanism.
Results
The mean rotation according to Raimondi and coronal correction was not sig. affected (72 (± 12) % in the SI-Group versus 68 (± 15) % in the DI-Group), even when flexibility was respected (Cincinnati Correction Index CCI was 2.9 (± 4.9) versus 3.5 (± 4.4). (p < 0.01). The gain of kyphosis was sig greater (2.7°) in the SI-group, but not clinical relevant.
Conclusion
The use of DI screws for apical derotation did not provide an advantage for coronal correction or derotation in thoracic curves. Presumably after translation is performed in the DI-group, there was too much tension and friction in the construct impeding further derotation. Simultaneous translation and derotation in the SI-group, with the convex rod being the COR, yielded similar correction with better kyphosis and was faster and more economic.
Funder
Johann Wolfgang Goethe-Universität, Frankfurt am Main
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Surgery
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献