Abstract
Abstract
Purpose
We evaluated the long-term safety, mobility and complications of cervical total disc arthroplasty with the Baguera®C prosthesis over 10 years.
Methods
We included 91 patients treated by arthroplasty for cervical degenerative disc disease. A total of 113 prostheses were implanted (50 one-level, 44 two-level and 19 hybrid constructs). They were assessed for complications, clinically, with NDI and SF-12 questionnaires and by independent radiologists for ROM, HO, disc height and adjacent level degeneration.
Results
No spontaneous migration, loss of fixation, subsidence, vascular complication or dislocation were observed. The reoperation rate was 1%. About 82.7% of the patients were pain free. About 9.9% were taking occasional grade I painkillers. Motricity and sensitivity were preserved in 98.8% and 96.3%. The NDI showed an average functional disability of 17.58%, 26% lower than preoperatively. The SF-12 scores were close to normal health. The average ROM at the treated level was 7.4°. Motion was preserved in 86.6%. Lack of motion was observed in 13.4%. Grades II and III H0 were present in 53.7% and 31.7%, respectively, Grade IV was present in 13.4%. Motion was preserved in 100% of the grades 0–III. The preoperative adjacent level disc height of 4.3 mm remained stable during all the follow-ups at 4.4 mm and 4.2 mm, respectively, at 5 and 10 years.
Conclusions
After 10 years, cervical arthroplasty with the Baguera®C prosthesis presents excellent safety and functional results and low complications. Motion was preserved in 86.6%, with a 7.4° ROM. Although common, HO did not hinder motion. Adjacent disc height preservation confirms some adjacent level degeneration protection.
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Surgery
Reference26 articles.
1. Depreitere B, Fransen P, Goffin J, Lubansu A, Put E, Scordidis V, Van Schaeybroeck P (2008) Recommendations of good practice for cervical disc replacement. In: Presented at the Société Belge de Neurochirurgie, Liège
2. Fransen P, Pointillart V (2016) Arthroplasty with the Baguera®C cervical disc prosthesis: review of the scientific background, clinical and radiographic evidences. J Spine Neurosurg 5:6
3. Joaquim A, Riew K (2017) Multilevel cervical arthroplasty: current evidence. A systematic review. Neurosurg Focus 42(2):E4
4. Fransen P, Hansen-Algenstaedt N, Chatzisotiriou A, Gonzalez Noriega D, Verheyden J, VanHecke W, Pointillart V (2016) Radiographic outcome and adjacent segment evaluation two years after cervical disc replacement with the Baguera®C prosthesis as treatment of degenerative cervical disc disease. J Spine 5:2
5. McAfee PC, Cunningham BW, Devine J, Williams E, Yu-Yahiro J (2003) Classification of heterotopic ossification (HO) in artificial disk replacement. J Spinal Disord Tech 16(4):384–389
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献