Abstract
Abstract
Purpose
To evaluate the diagnostic accuracy of a commercially available test kit for noninvasive prenatal determination of the fetal RhD status (NIPT-RhD) with a focus on early gestation and multiple pregnancies.
Methods
The FetoGnost RhD assay (Ingenetix, Vienna, Austria) is routinely applied for clinical decision making either in woman with anti-D alloimmunization or to target the application of routine antenatal anti-D prophylaxis (RAADP) to women with a RhD positive fetus. Based on existing data in the laboratory information system the newborn’s serological RhD status was compared with NIPT RhD results.
Results
Since 2009 NIPT RhD was performed in 2968 pregnant women between weeks 5 + 6 and 40 + 0 of gestation (median 12 + 6) and conclusive results were obtained in 2888 (97.30%) cases. Diagnostic accuracy was calculated from those 2244 (77.70%) cases with the newborn’s serological RhD status reported. The sensitivity of the FetoGnost RhD assay was 99.93% (95% CI 99.61–99.99%) and the specificity was 99.61% (95% CI 98.86–99.87%). No false-positive or false-negative NIPT RhD result was observed in 203 multiple pregnancies.
Conclusion
NIPT RhD results are reliable when obtained with FetoGnost RhD assay. Targeted routine anti-D-prophylaxis can start as early as 11 + 0 weeks of gestation in singleton and multiple pregnancies.
Publisher
Springer Science and Business Media LLC
Subject
Obstetrics and Gynecology,General Medicine
Cited by
12 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献