The use of the reconstruction plate in multiplanar tibial osteotomies in children

Author:

Schaaf Adam C.1,Morscher Melanie A.2,Weiner Dennis S.3

Affiliation:

1. Department of Orthopaedic Surgery, Akron Children’s Hospital and Summa Health System, 44302, Akron, OH USA

2. Pediatric Orthopaedic Research, Akron Children’s Hospital, 44302, Akron, OH USA

3. Department of Pediatric Orthopaedic Surgery, Akron Children’s Hospital, Northeastern Ohio Universities Colleges of Medicine and Pharmacy, 300 Locust Street, Ste. 160, 44302-1821, Akron, OH USA

Abstract

Purpose External fixation and cross-pin fixation appear to be the two most commonly used forms of fixation after a tibial osteotomy in children described in the literature. The purpose of this study is to describe our experience using a properly bent and contoured reconstruction plate for mismatched surfaces after a multiplanar tibial osteotomy. Methods A retrospective review was conducted of 37 multiplanar tibial osteotomy surgeries in 23 children performed by a single surgeon using a reconstruction plate for internal fixation. A low fibular osteotomy and tibial osteotomy that required contouring and shaping of the plate were performed in all cases. A proximal tibial osteotomy was performed in 30 cases and a distal osteotomy in seven cases. All cases were reinforced with a long-leg cast. All charts were reviewed for intra- and postoperative complications. The surgery using the reconstruction plate internal fixation was considered to be a success if there was healing of the osteotomy and no hardware failure. Results A properly bent and contoured reconstruction plate conformed well to the mismatched surfaces after tibial osteotomy. Hardware was removed in all but two cases, on average 7 months after surgery. There were no hardware failures. No child developed a deep wound infection or neurovascular complication, including compartment syndrome. Only two complications in 37 surgeries (5%) were encountered and were typical of any type of internal fixation. One child required an exploratory procedure because of screw extrusion and one child developed a post-plate removal fracture. Conclusions The reconstruction plate is very malleable and can be contoured to fit in nearly every direction to accommodate mismatched appositional surfaces. It has been successfully employed in 37 consecutive cases of multiplanar tibial osteotomy in children with relatively few complications, none directly related to the plate.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Pediatrics, Perinatology and Child Health

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3