Sensitivity of virtual non-contrast dual-energy CT urogram for detection of urinary calculi: a systematic review and meta-analysis

Author:

McCoombe Katherine,Dobeli Karen,Meikle Steven,Llewellyn Stacey,Kench Peter

Abstract

Abstract Objective To determine the sensitivity of dual-energy (DE) virtual non-contrast computed tomography (vNCT), generated from the excretory phase of a CT urogram, compared to true non-contrast CT (tNCT) for the detection of urinary calculi. Methods A search of multiple medical literature databases was performed using predetermined search terms. Inclusion and exclusion criteria were applied, and bias risk was assessed by two independent reviewers using the quality assessment of diagnostic accuracy studies (QUADAS) tool. Collated estimates of sensitivity were generated, and sources of heterogeneity were identified and reviewed. Results Thirteen studies (1760 patients; 1740 urinary calculi) were included for sensitivity assessment. Pooled sensitivity for urinary calculi on vNCT was 78.1% (95% CI: 70.2 to 85.0%); however, heterogeneity between studies was very high (I2 = 92.0%). Sources of heterogeneity between studies were explored through subgroup analysis by categorising studies according to slice thickness (≥ 2 mm and < 2 mm), use of oral hydration, and use of intravenous furosemide. Pooled sensitivity for detection of urinary calculi on vNCT for studies that used oral hydration and < 2 mm slice thickness was 92.2% (95% CI: 89.5 to 94.5%). Pooled specificity was not performed as true negatives were not reported in most studies. Potential sources of bias were identified in included studies. Conclusion vNCT demonstrated a moderate pooled sensitivity compared to tNCT for the detection of urinary calculi in split bolus CT urogram protocols. However, subgroup analysis suggests higher sensitivity when employing oral hydration and < 2 mm slice thickness or increment. Key Points vNCT demonstrated moderate pooled sensitivity for the detection of urinary calculi in split bolus CT urogram protocols. Subgroup analysis suggested higher sensitivity with oral hydration and < 2 mm slice thickness or increment.

Funder

University of Sydney

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3