Visualization of wrist anatomy—a comparison between 7T and 3T MRI

Author:

Götestrand SimonORCID,Björkman AndersORCID,Björkman-Burtscher Isabella M.ORCID,Kristiansson Ingvar,Aksyuk Elenya,Szaro PawelORCID,Markenroth Bloch KarinORCID,Geijer MatsORCID

Abstract

Abstract Objective Injuries to the wrist are, due to its small size and complex anatomical structures, difficult to assess by MR, and surgical interventions such as diagnostic arthroscopy are often necessary. Therefore, improved visualization using non-invasive methods could be of clinical value. As a first step of improvement, the purpose of this study was to evaluate visualization of anatomical structures at 7T compared with 3T MR. Methods Eighteen healthy volunteers (three males and three females from each age decade between 20 and 49 years) were examined with 7T and 3T MR. Four musculoskeletal radiologists graded 2D and 3D images on a five-level grading scale for visibility of ligaments, cartilage, nerves, trabecular bone, and tendons, as well as overall image quality (i.e., edge sharpness, perceived tissue contrast, and presence of artefacts). Statistical analysis was done using a visual grading characteristics (VGC) analysis. Results Visibility of cartilage, trabecular bone, tendons, nerves, and ligaments was graded significantly higher at 7T with an area under the curve (AUCVGC) of 0.62–0.88 (95% confidence interval [CI] 0.50–0.97, p = < 0.0001–0.03) using either 2D or 3D imaging. Imaging with 3T was not graded as superior to 7T for any structure. Image quality was also significantly superior at 7T, except for artefacts, where no significant differences were found. Conclusions Tendons, trabecular bone, nerves, and ligaments were all significantly better visualized at 7T compared to 3T. Key Points MRI of the wrist at 7T with a commercially available wrist coil is feasible at similar acquisition times as for 3T MRI. The current study showed 7T to be superior to 3T in the visualization of anatomical structures of the wrist, including ligaments, tendons, nerves, and trabecular bone. Image quality was significantly superior at 7T, except for artefacts, where no significant differences were found.

Funder

Sahlgrenska Universitetssjukhuset

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3