Notifications and alerts in patient dose values for computed tomography and fluoroscopy-guided interventional procedures

Author:

Vano EliseoORCID,Loose Reinhard,Frija Guy,Paulo Graciano,Efstathopoulos Efstathios,Granata Claudio,Corridori Riccardo,Torresin Alberto,Andersson Jonas S.,Tsapaki Virginia,Ammon Josefin,Hoeschen Christoph,

Abstract

Abstract The terms “notifications” and “alerts” for medical exposures are used by several national and international organisations. Recommendations for CT scanners have been published by the American Association of Physicists in Medicine. Some interventional radiology societies as well as national authorities have also published dose notifications for fluoroscopy-guided interventional procedures. Notifications and alerts may also be useful for optimisation and to avoid unintended and accidental exposures. The main interest in using these values for high-dose procedures (CT and interventional) is to optimise imaging procedures, reducing the probability of stochastic effects and avoiding tissue reactions. Alerts in X-ray systems may be considered before procedures (as in CT), during procedures (in some interventional radiology systems), and after procedures, when the patient radiation dose results are known and processed. This review summarises the different uses of notifications and alerts to help in optimisation for CT and for fluoroscopy-guided interventional procedures as well as in the analysis of unintended and accidental medical exposures. The paper also includes cautions in setting the alert values and discusses the benefits of using patient dose management systems for the alerts, their registry and follow-up, and the differences between notifications, alerts, and trigger levels for individual procedures and the terms used for the collective approach, such as diagnostic reference levels. Key Points Notifications and alerts on patient dose values for computed tomography (CT) and fluoroscopy-guided interventional procedures (FGIP) allow to improve radiation safety and contribute to the avoidance of radiation injuries and unintended and accidental exposures. Alerts may be established before the imaging procedures (as in CT) or during and after the procedures as for FGIP. Dose management systems should include notifications and alerts and their registry for the hospital quality programmes.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Reference25 articles.

1. NEMA. National Electrical Manufacturers Association. Computed tomography dose check. NEMA XR-25-2010. Available at: http://www.nema.org/stds/xr25.cfm. Second version revised in 2019: NEMA Standards Publication XR 25-2019

2. FDA. Letter to the Medical Imaging Technology Alliance regarding CT recommendations (Nov. 2010). https://www.fda.gov/radiation-emitting-products/initiative-reduce-unnecessary-radiation-exposure-medical-imaging/letter-medical-imaging-technology-alliance-regarding-ct-recommendations. Accessed 24 April 2021)

3. American Association of Physicists in Medicine. AAPM recommendations regarding notification and alert values for CT scanners: guidelines for use of the NEMA XR 25 CT dose-check standard. Guidelines version 1.0. April 2011. Available at: http://www.aapm.org/pubs/CTProtocols/documents/NotificationLevelsStatement_2011-04-27.pdf

4. IEC 60601-2-44:2009+AMD1:2012+AMD2:2016 CSV : Medical electrical equipment - Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography. https://webstore.iec.ch/publication/24442

5. Stecker MS, Balter S, Towbin RB et al (2009) SIR Safety and Health Committee; CIRSE Standards of Practice Committee. Guidelines for patient radiation dose management. J Vasc Interv Radiol. 20(7 Suppl):S263–S273. https://doi.org/10.1016/j.jvir.2009.04.037