Radiation Exposure in Interventional Stroke Treatment

Author:

Bärenfänger FelixORCID,Schramm Peter,Rohde Stefan

Abstract

Abstract Purpose To evaluate patient-related radiation exposure in interventional stroke treatment by analyzing data from the German Society for Interventional Radiology and Minimally Invasive Therapy (DeGIR) and the German Society of Neuroradiology (DGNR) quality registry from 2019–2021. Methods The DeGIR/DGNR registry is the largest database of radiological interventions in Germany. Since the introduction of the registry in 2012, the participating hospitals have entered clinical and dose-related data on the procedures performed. To evaluate the current diagnostic reference level (DRL) for mechanical thrombectomy (MT) in stroke patients, we analyzed interventional data from 2019 to 2021 with respect to the reported dose area product (DAP) and factors that might contribute to the radiation dose, such as the localization of the occlusion, technical success using the modified treatment in cerebral ischemia (mTICI) score, number of passages, technical approach, additional intracranial/extracranial stenting, and case volume per center. Results A total of 41,538 performed MTs from 180 participating hospitals were analyzed. The median DAP for MT was 7337.5 cGy∙cm2 and the corresponding interquartile range (IQR) Q25 = 4064 cGy∙cm2 to Q75 = 12,263 cGy∙cm2. In addition, we discovered that the dose was significantly influenced by occlusion location, number of passages, case volume per center, recanalization score, and additional stenting. Conclusion We conducted a retrospective study on radiation exposure during MT in Germany. Based on the results of more than 41,000 procedures, we observed that the DRL of 14,000 cGy·cm2 is currently appropriate but may be lowered over the next years. Furthermore, we identified several factors that contribute to high radiation exposure. This can aid in detecting the cause of an exceeded DRL and optimize the treatment workflow.

Funder

Private Universität Witten/Herdecke gGmbH

Publisher

Springer Science and Business Media LLC

Subject

Neurology (clinical),Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3