Abstract
AbstractThe occurrence of data outliers in PIV measurements remains nowadays a problematic issue; their effective detection is relevant to the reliability of PIV experiments. This study proposes a novel approach to outliers detection from time-averaged three-dimensional PIV data. The principle is based on the agreement of the measured data to the turbulent kinetic energy (TKE) transport equation. The ratio between the local advection and production terms of the TKE along the streamline determines the admissibility of the inquired datapoint. Planar and 3D PIV experimental datasets are used to demonstrate that in the presence of outliers, the turbulent transport (TT) criterion yields a large separation between correct and erroneous vectors. The comparison between the TT criterion and the state-of-the-art universal outlier detection from Westerweel and Scarano (Exp Fluids 39:1096–1100, 2005) shows that the proposed criterion yields a larger percentage of detected outliers along with a lower fraction of false positives for a wider range of possible values chosen for the threshold.
Graphical abstract
Publisher
Springer Science and Business Media LLC
Subject
Fluid Flow and Transfer Processes,General Physics and Astronomy,Mechanics of Materials,Computational Mechanics
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献