Peridialytic and intradialytic blood pressure metrics are not valid estimates of 44-h ambulatory blood pressure in patients with intradialytic hypertension

Author:

Theodorakopoulou Marieta P.,Alexandrou Maria-Eleni,Iatridi Fotini,Karpetas Antonios,Geladari Virginia,Pella Eva,Alexiou Sophia,Sidiropoulou Maria,Ziaka Stavroula,Papagianni Aikaterini,Sarafidis PantelisORCID

Abstract

Abstract Purpose In contrast to peridialytic blood pressure (BP), intradialytic and home BP measurements are accurate metrics of ambulatory BP load in hemodialysis patients. This study assessed the agreement of peridialytic, intradialytic, and scheduled interdialytic recordings with 44-h BP in a distinct hemodialysis population, patients with intradialytic hypertension (IDH). Methods This study included 45 IDH patients with valid 48-h ABPM and 197 without IDH. With 44-h BP used as reference method, we tested the accuracy of the following BP metrics: Pre- and post-dialysis, mean and median intradialytic, mean intradialytic plus pre/post-dialysis, and scheduled interdialytic BP (out-of-dialysis day: mean of 8:00am/8:00 pm readings). Results In IDH patients, peridialytic and intradialytic BP metrics showed at best moderate correlations, while averaged interdialytic SBP/DBP exhibited strong correlation (r = 0.882/r = 0.855) with 44-h SBP/DBP. Bland–Altman plots showed large between-method-difference for peri- and intradialytic-BP, but only + 0.7 mmHg between-method difference and good 95% limits of agreement for averaged interdialytic SBP. The sensitivity/specificity and κ-statistic for diagnosing 44-h SBP ≥ 130 mmHg were low for pre-dialysis (72.5/40.0%, κ-statistic = 0.074) and post-dialysis (90.0/0.0%, κ-statistic = − 0.110), mean intradialytic (85.0/40.0%, κ-statistic = 0.198), median intradialytic (85.0/60.0%, κ-statistic = 0.333), and intradialytic plus pre/post-dialysis SBP (85.0/20.0%, κ-statistic = 0.043). Averaged interdialytic SBP showed high sensitivity/specificity (97.5/80.0%) and strong agreement (κ-statistic = 0.775). In ROC analyses, scheduled interdialytic SBP/DBP had the highest AUC (0.967/0.951), sensitivity (90.0/88.0%), and specificity (100.0/90.0%). Conclusion In IDH patients, only averaged scheduled interdialytic but not pre- and post-dialysis, nor intradialytic BP recordings show reasonable agreement with ABPM. Interdialytic BP recordings only could be used for hypertension diagnosis and management in these subjects.

Funder

Aristotle University of Thessaloniki

Publisher

Springer Science and Business Media LLC

Subject

Urology,Nephrology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3