Reduction of permanent pacemaker implantation by using the cusp overlap technique in transcatheter aortic valve replacement: a meta-analysis
-
Published:2023-01-19
Issue:5
Volume:112
Page:633-644
-
ISSN:1861-0684
-
Container-title:Clinical Research in Cardiology
-
language:en
-
Short-container-title:Clin Res Cardiol
Author:
Rawish EliasORCID, Macherey Sascha, Jurczyk Dominik, Pätz Toni, Jose John, Stiermaier Thomas, Eitel Ingo, Frerker Christian, Schmidt Tobias
Abstract
Abstract
Background
The need for permanent pacemaker (PPM) implantation is a common complication after transcatheter aortic valve replacement (TAVR). Deep implantation position is a risk factor for PPM implantation. Thus, in the field of self-expandable (SE) transcatheter heart valves (THV) cusp overlap projection (COP) technique was implemented to reduce parallax, allowing a more precise guidance of implantation depth.
Aims
This meta-analysis aims to report the outcome of patients undergoing TAVR with SE THV using COP versus conventional implantation technique (CIT).
Methods
Systematical search in MEDLINE and EMBASE yielded five observational controlled studies comparing both implantation techniques for the SE Evolut prosthesis (Medtronic Intern. Ltd., CA, USA) and fulfilling the inclusion criteria for meta-analysis.
Results
Totally, 1227 patients were included, comprising 641 who underwent COP and 586 CIT TAVR. Incidence of post-procedural need for PPM implantation was significantly lower in COP group (9.8% vs 20.6%; OR = 0.43; p < 0.00001). This was accompanied by significantly higher implantation position in COP group (mean difference distance from distal end of the intraventricular portion of the THV to the non-coronary cusp (NCC): − 1.03 mm; p = 0.00001). Incidence of new-onset left bundle branch block did not differ. Regarding procedural and 30-day mortality, technical success, post-procedural aortic regurgitation, and rates of multiple device implantation, no difference between COP and CIT was found.
Conclusion
COP is an effective and safe implantation technique to reduce the need for a permanent pacemaker implantation during TAVR with SE Evolut prosthesis.
Graphical abstract
Funder
Universität zu Lübeck
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine,General Medicine
Reference28 articles.
1. Vahanian A, Beyersdorf F, Praz F, Milojevic M, Baldus S, Bauersachs J, Capodanno D, Conradi L, De Bonis M, De Paulis R, Delgado V, Freemantle N, Gilard M, Haugaa KH, Jeppsson A, Jüni P, Pierard L, Prendergast BD, Sádaba JR, Tribouilloy C, Wojakowski W, E.E.S.D. Group (2022) 2021 ESC/EACTS Guidelines for the management of valvular heart disease: developed by the Task Force for the management of valvular heart disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur Heart J 43(7):561–632 2. Cribier A, Eltchaninoff H, Bash A, Borenstein N, Tron C, Bauer F, Derumeaux G, Anselme F, Laborde F, Leon MB (2002) Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation 106(24):3006–3008 3. Anwaruddin S, Desai Nimesh D, Vemulapalli S, Marquis-Gravel G, Li Z, Kosinski A, Michael JR (2021) Evaluating out-of-hospital 30-day mortality after transfemoral transcatheter aortic valve replacement. JACC 14(3):261–274 4. Fujita B, Schmidt T, Bleiziffer S, Bauer T, Beckmann A, Bekeredjian R, Möllmann H, Walther T, Landwehr S, Hamm C, Beyersdorf F, Katus HA, Harringer W, Ensminger S, Frerker C (2020) Impact of new pacemaker implantation following surgical and transcatheter aortic valve replacement on 1-year outcome. Eur J Cardiothorac Surg 57(1):151–159 5. Mahajan S, Gupta R, Malik AH, Mahajan P, Aedma SK, Aronow WS, Mehta SS, Lakkireddy DR (2021) Predictors of permanent pacemaker insertion after TAVR: a systematic review and updated meta-analysis. J Cardiovasc Electrophysiol 32(5):1411–1420
Cited by
17 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|