Balloon technologies for pulmonary vein isolation—12-month outcome and comparison of the novel radiofrequency balloon with the cryoballoon in patients with paroxysmal atrial fibrillation

Author:

van den Bruck Jan-HendrikORCID,Wörmann JonasORCID,Sultan ArianORCID,Filipovic Karlo,Seuthe KatharinaORCID,Erlhöfer Susanne,Scheurlen CorneliaORCID,Dittrich Sebastian,Schipper Jan-HendrikORCID,Lüker JakobORCID,Steven DanielORCID

Abstract

Abstract Background The cryoballoon (CB) has become a standard tool for pulmonary vein isolation (PVI), but the technology is limited in certain ways. A novel RF-balloon (Heliostar™, Biosense Webster, CA, USA) promises the advantages of a balloon technology in combination with 3D mapping. Methods To assess procedural data and outcome, all patients undergoing RF-balloon PVI were included and compared with data from consecutive patients undergoing CB PVI for paroxysmal AF. Results A total of 254 patients (63 ± 13 years, 54% male) were included: 30 patients undergoing RF-balloon and 224 patients CB PVI. Baseline parameters were comparable. Procedure duration (104.3 ± 35.3 min vs. 69.9 ± 23.1 min; p ≤ 0.001) and fluoroscopy time (16.3 ± 7.1 min vs. 11.6 ± 4.9 min; p ≤ 0.001) were longer using the RF-balloon; ablation time (43.5 ± 17.9 vs. 36.4 ± 15.6; p = 0.08) did not differ, and time-to-isolation (TTI) was shorter (18.2 ± 7.0 s vs. 62.8 ± 35.1 s; p ≤ 0.001). Second-generation RF-balloon cases showed shorter ablation time and TTI at comparable procedure duration and fluoroscopy time. One pericardial effusion occurred with the RF-balloon due to complicated transseptal access. During CB PVI in 4/224 patients (1.8%), a phrenic nerve palsy was observed. After 12 months, 78% of patients after RF-balloon and 81% of patients after CB PVI (p = 0.5) were free from atrial arrhythmias. Conclusion The RF-balloon was safe and effective. Compared with the CB, TTI was shorter, but procedure durations and fluoroscopy times were longer. This can be attributed to a learning curve and the initial necessity for separate 3D map preparation. Considering the results with the second-generation RF-balloon, more experience is needed to determine the potential benefits. Graphical Abstract

Funder

Universität zu Köln

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3