Abstract
Abstract
Purpose
Reduction in iodinated contrast medium (CM) dose is highly motivated. Our aim was to evaluate if a 50% reduction of CM, while preserving image quality, is possible in brain CT angiography (CTA) using virtual monoenergetic images (VMI) on spectral CT. As a secondary aim, we evaluated if VMI can salvage examinations with suboptimal CM timing.
Methods
Consecutive patients older than 18 years without intracranial stenosis/occlusion were included. Three imaging protocols were used: group 1, full CM dose; group 2, 50% CM dose suboptimal timing; and group 3, 50% CM dose optimized timing.
Attenuation, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured in the internal carotid artery, M2 segment of the middle cerebral artery, and white matter for conventional images (CI) and VMI (40–200 keV). Qualitative image quality for CI and VMI (50 and 60 keV) was rated by 4 experienced reviewers.
Results
Qualitatively and quantitatively, VMI (40–60 keV) improved image quality within each group. Significantly higher attenuation and CNR was found for group 3 VMI 40–50 keV, with unchanged SNR, compared to group 1 CI. Group 3 VMI 50 keV also received significantly higher rating scores than group 1 CI. Group 2 VMI (40–50 keV) had significantly higher CNR compared to group 3 CI, but the subjective image quality was similar.
Conclusion
VMI of 50 keV with 50% CM dose increases qualitative and quantitative image quality over CI with full CM dose. Using VMI reduces non-diagnostic examinations and may salvage CTA examinations deemed non-diagnostic due to suboptimal timing.
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine,Neurology (clinical),Radiology, Nuclear Medicine and imaging
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献