Abstract
AbstractEurocode-2 (EC2) empirical equation for fire resistance of RC columns is very sensitive to the value of column capacity at normal temperature conditions $$N_{Rd}$$
N
Rd
. Techniques to determine $$N_{Rd}$$
N
Rd
accurately for eccentric slender columns are difficult and computationally demanding; thus, adopting simplifications leads to unsatisfactory results in many column cases. Another shortcoming of EC2 equation is that it does not include an explicit term regarding the effect of load eccentricity on fire resistance. In this paper, a simplified method, as an attempt to overcome EC2 method defects, is developed to determine the fire resistance of RC columns using fire-resistance-column-curves. A rational numerical model is used to analyze various series of RC columns with different geometric, material, and loading properties at elevated temperatures. The results of the numerical study are utilized to construct different fire-resistance-column-curves from which simplified design equations are developed to predict the fire resistance of fixed- and pinned-end RC columns. The validity of the method is established with the aid of experimental data and it was found that in most cases, there is good agreement between assessed and test columns. It was also found that the proposed equations provide sufficiently safe predictions when appropriate material safety factors are adopted. The applicability of the proposed method to fire resistance design of RC columns is illustrated through numerical examples.
Publisher
Springer Science and Business Media LLC
Reference16 articles.
1. Dotreppe JC, Franssen JM, Vanderzeypen Y (1999) Calculation method for design of reinforced concrete columns under fire conditions. ACI Struct J 96(1):9–18
2. Franssen JM, Dotreppe JC (2003) Fire tests and calculation methods for circular concrete columns. Fire Technol 39:80–97
3. Franssen JM (2000) Design of concrete columns based on EC2 tabulated data-a critical review. First International Workshop Structures in Fire, Copenhagen
4. prEN 1992-1-2: Eurocode 2 (2004) Design of concrete structures—part 1–2: general rules-structural fire design. Brussels.
5. Kodur VKR, Raut N (2012) A simplified approach for predicting fire resistance of reinforced concrete columns under biaxial bending. Eng Struct 41:428–443