Safe implementation of hand held steerable laparoscopic instruments: a survey among EAES surgeons

Author:

Hardon S. F.ORCID,Rahimi A. M.,Postema R. R.,Willuth E.,Mintz Y.,Arezzo A.,Dankelman J.,Nickel F.,Horeman T.,Baldari L.,Boni L.,Chand M.,Ficuciello F.,Fuchs H.,Horeman T.,Inaki N.,Jimenez-Rodrigues R.,Kim Y. W.,Manfredi L.,Marconi S.,Mascagni P.,Perretta S.,Schijven M.,Mylonas G.,Myśliwiec P.,Nickel F.,Petz W.,Sagiv C.,Sánchez-Margallo J. A.,Sánchez-Margallo F.,

Abstract

AbstractThe complexity of handheld steerable laparoscopic instruments (SLI) may impair the learning curve compared to conventional instruments when first utilized. This study aimed to provide the current state of interest in the use of SLI, the current use of these in daily practice and the type of training which is conducted before using SLI in the operating room (OR) on real patients. An online survey was distributed by European Association of Endoscopic Surgery (EAES) Executive Office to all active members, between January 4th and February 3rd, 2020. The survey consisted of 14 questions regarding the usage and training of steerable laparoscopic instruments. A total of 83 members responded, coming from 33 different countries. Twenty three percent of the respondents using SLI, were using the instruments routinely and of these 21% had not received any formal training in advance of using the instruments in real patients. Of all responding EAES members, 41% considered the instruments to potentially compromise patient safety due to their complexity, learning curve and the inexperience of the surgeons. The respondents reported the three most important aspects of a possible steerable laparoscopic instruments training curriculum to be: hands-on training, safe tissue handling and suturing practice. Finally, a major part of the respondents consider force/pressure feedback data to be of significant importance for implementation of training and assessment of safe laparoscopic and robotic surgery. Training and assessment of skills regarding safe implementation of steerable laparoscopic instruments is lacking. The respondents stressed the need for specific hands-on training during which feedback and assessment of skills should be guaranteed before operating on real patients.

Publisher

Springer Science and Business Media LLC

Subject

Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3