Author:
Yao Kai,Liu Yunchuan,Zhou Yanping,Wang Xuerong,Wang Qianqian,Ma Yandong,Yao Cui
Funder
State Administration for Science, Technology and Industry for National Defense
Publisher
Springer Science and Business Media LLC
Reference18 articles.
1. ASTM C177-13, Standard test method for steady-state heat flux measurements and thermal transmission properties by means of the guarded hot plate apparatus (ASTM, West Conshohocken, 2013)
2. ISO 8302:1991, Thermal insulation: determination of steady state thermal resistance and related properties: guarded hot plate apparatus (ISO, Geneva, 1991)
3. J. Xaman, L. Lira, J. Arce, Analysis of the temperature distribution in a guarded hot plate apparatus for measuring thermal conductivity. Appl. Therm. Eng. 29, 617–623 (2009). https://doi.org/10.1016/j.applthermaleng.2008.03.033
4. V. Scoarnec, J. Hameury, B. Hay, A new guarded hot plate designed for thermal-conductivity measurement at High temperature. Int. J. Thermophys. 36, 540–556 (2015). https://doi.org/10.1007/s10765-014-1794-y
5. S. Dobois, F. Lebeau, Design, construction and validation of a guarded hot plate apparatus for thermal conductivity measurement of high thickness crop-based specimens. Mater. Struct. 48, 407–421 (2015). https://doi.org/10.1617/s11527-013-0192-4
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献