Abstract
Abstract
Purpose
Present (i) an infrared (IR)-based Process Analytical Technology (PAT) installed in a lab-scale freeze-dryer and (ii) a micro freeze-dryer (MicroFD®) as effective tools for freeze-drying design space calculation of the primary drying stage.
Methods
The case studies investigated are the freeze-drying of a crystalline (5% mannitol) and of an amorphous (5% sucrose) solution processed in 6R vials. The heat (Kv) and the mass (Rp) transfer coefficients were estimated: tests at 8, 13 and 26 Pa were carried out to assess the chamber pressure effect on Kv. The design space of the primary drying stage was calculated using these parameters and a well-established model-based approach. The results obtained using the proposed tools were compared to the ones in case Kv and Rp were estimated in a lab-scale unit through gravimetric tests and a thermocouple-based method, respectively.
Results
The IR-based method allows a non-gravimetric estimation of the Kv values while with the micro freeze-dryer gravimetric tests require a very small number of vials. In both cases, the obtained values of Kv and Rp, as well as the resulting design spaces, were all in very good agreement with those obtained in a lab-scale unit through the gravimetric tests (Kv) and the thermocouple-based method (Rp).
Conclusions
The proposed tools can be effectively used for design space calculation in substitution of other well-spread methods. Their advantages are mainly the less laborious Kv estimation process and, as far as the MicroFD® is concerned, the possibility of saving time and formulation material when evaluating Rp.
Publisher
Springer Science and Business Media LLC
Subject
Pharmacology (medical),Organic Chemistry,Pharmaceutical Science,Pharmacology,Molecular Medicine,Biotechnology
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献