The European intercomparison of in-vivo monitoring laboratories: the EIVIC-2020 project

Author:

Franck D.ORCID,Meisenberg O.ORCID,Beaumont T.ORCID,Buchholz W.ORCID,López M. A.ORCID,Navarro J. F.ORCID,Pérez B.ORCID,Hürkamp K.ORCID,Breustedt B.ORCID,Vanhavere F.ORCID

Abstract

AbstractThe EIVIC project was launched in 2020, and the main goal was the organisation of a European intercomparison of in-vivo monitoring laboratories dealing with direct measurements of gamma-emitting radionuclides incorporated into the body of exposed workers. This project was organised jointly by members of EURADOS Working Group 7 on internal dosimetry (WG7), the Federal Office for Radiation Protection (BfS, Germany) and the Radioprotection and Nuclear Safety Institute (IRSN, France). The objective was to assess the implementation of individual-monitoring requirements in EU Member States on the basis of in-vivo measurements and to gain insight into the performance of in-vivo measurements using whole-body counters. In this context, a total of 41 in-vivo monitoring laboratories from 21 countries, together with JRC (EC) and IAEA participated. The results were submitted in terms of activity (Bq) of the radionuclides identified inside phantoms that were circulated to all participants. The measured data were compared with reference activity values to evaluate the corresponding bias according to the standards ISO 28218 and ISO 13528. In general, the results of the different exercises are good, and most facilities are in conformity with the criteria for the bias and z-scores in the ISO standards. Furthermore, information about technical and organisational characteristics of the participating laboratories was collected to test if they had a significant influence on the reported results.

Funder

European Commission, Directorate-General Energy

Bundesamt für Strahlenschutz

Publisher

Springer Science and Business Media LLC

Reference14 articles.

1. Benyakoub H (2017) Caractéristiques d’un jeu de 280 sources radioactives pour équiper un fantôme anthropomorphe IGOR (Characteristics of a set of 280 radioactive sources to equip an IGOR anthropomorphic phantom; in French, internal report). IRSN, Le Vésinet, France

2. Berard P, Franck D (2011) National and international interlaboratories comparisons organised in France: a tool for the validation of in-vitro and in-vivo methods. Radiat Prot Dosim 144:287–290

3. EC (2014) European Community, Council Directive 84/467/EURATOM of 3 September 1984 amending directive 80/836/EURATOM as regards the basic safety standards for health protection of the general public and workers against the dangers of ionizing radiation. Official J No L 265(05):10

4. Franck D, Meisenberg O, López MA, Beaumont T, Buchholz W, Navarro JF, Pérez B, Hürkamp K, Vanhavere F. (2023) EURADOS Report 2023-03 “EIVIC-2020: European In-Vivo Intercomparison Exercise 2020 - Organisation of a European Interlaboratory Comparison on Whole-Body Counting”. ISBN 978-3-943701-35-7. https://doi.org/10.12768/hmma-d768

5. ICRU (1992) International commission on radiation units and measurements. Phantoms and computational models in therapy, diagnosis and protection ICRU, report 48. Oxford University Press, Oxford