Abstract
Abstract
Purpose
Kinetics of cardiorespiratory parameters (CRP) in response to work rate (WR) changes are evaluated by pseudo-random binary sequences (PRBS testing). In this study, two algorithms were applied to convert responses from PRBS testing into appropriate impulse responses to predict steady states values and responses to incremental increases in exercise intensity.
Methods
13 individuals (age: 41 ± 9 years, BMI: 23.8 ± 3.7 kg m−2), completing an exercise test protocol, comprising a section of randomized changes of 30 W and 80 W (PRBS), two phases of constant WR at 30 W and 80 W and incremental WR until subjective fatigue, were included in the analysis. Ventilation ($$\dot{V}_{{\text{E}}}$$
V
˙
E
), O2 uptake ($$\dot{V}{\text{O}}_{2}$$
V
˙
O
2
), CO2 output ($$\dot{V}{\text{CO}}_{2}$$
V
˙
CO
2
) and heart rate (HR) were monitored. Impulse responses were calculated in the time domain and in the frequency domain from the cross-correlations of WR and the respective CRP.
Results
The algorithm in the time domain allows better prediction for $$\dot{V}{\text{O}}_{2}$$
V
˙
O
2
and $$\dot{V}{\text{CO}}_{2}$$
V
˙
CO
2
, whereas for $$\dot{V}_{{\text{E}}}$$
V
˙
E
and HR the results were similar for both algorithms. Best predictions were found for $$\dot{V}{\text{O}}_{2}$$
V
˙
O
2
and HR with higher (3–4%) 30 W steady states and lower (1–4%) values for 80 W. Tendencies were found in the residuals between predicted and measured data.
Conclusion
The CRP kinetics, resulting from PRBS testing, are qualified to assess steady states within the applied WR range. Below the ventilatory threshold, $$\dot{V}{\text{O}}_{2}$$
V
˙
O
2
and HR responses to incrementally increasing exercise intensities can be sufficiently predicted.
Funder
bundesministerium für wirtschaft und energie
Deutsche Sporthochschule Köln (DSHS)
Publisher
Springer Science and Business Media LLC
Subject
Physiology (medical),Public Health, Environmental and Occupational Health,Orthopedics and Sports Medicine,General Medicine,Public Health, Environmental and Occupational Health,Physiology
Reference32 articles.
1. Beltrame T, Gois MO, Hoffmann U, Koschate J, Hughson RL, Moraes Frade MC, Linares SN, da Silva TR, Catai AM (2020) Relationship between maximal aerobic power with aerobic fitness as a function of signal-to-noise ratio. J Appl Physiol 129:522–532
2. Bo L, Jun Z, Jixin Q (2006) Design and analysis of test signals for system identification. In: Alexandrov VN, van Albada GD, Sloot PMA, Dongarra JJ (eds) Lecture Notes in Computer Science: Bd. 3993. Computational science—ICCS 2006: 6th international conference, Reading, UK, May 28–31, 2006; proceedings (Bd. 3993, S. 593–600). Springer
3. DeLorey DS, Kowalchuk JM, Paterson DH (2004) Effects of prior heavy-intensity exercise on pulmonary O2 uptake and muscle deoxygenation kinetics in young and older adult humans. J Appl Physiol 97:998–1005
4. Drescher U, Koschate J, Hoffmann U (2015) Oxygen uptake and heart rate kinetics during dynamic upper and lower body exercise: an investigation by time-series analysis. Eur J Appl Physiol 115:1665–1672
5. Drescher U, Koschate J, Hoffmann U, Schneider S, Werner A (2018) Effect of acute ambient temperature exposure on cardio pulmonary and respiratory kinetics in men. Int J Hyperthermia 34:442–454
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献