Abstract
Abstract
Introduction
Microcurrent has been used to promote tissue healing after injury or to hasten muscle remodeling post exercise post exercise.
Purpose
To compare the effects of resistance training in combination with either, microcurrent or sham treatment, on-body composition and muscular architecture. Additionally, changes in performance and perceived delayed onset muscle soreness (DOMS) were determined.
Methods
Eighteen males (25.7 ± 7.6 years) completed an 8-week resistance training program involving 3 workouts per week (24 total sessions) wearing a microcurrent (MIC, n = 9) or a sham (SH, n = 9) device for 3-h post-workout or in the morning during non-training days. Measurements were conducted at pre and post intervention.
Results
Compared to baseline, both groups increased (p < 0.05) muscle thickness of the elbow flexors (MIC + 2.9 ± 1.4 mm; SH + 3.0 ± 2.4 mm), triceps brachialis (MIC + 4.3 ± 2.8 mm; SH + 2.7 ± 2.6 mm), vastus medialis (MIC + 1.5 ± 1.5 mm; SH + 0.9 ± 0.8 mm) and vastus lateralis (MIC + 6.8 ± 8.0 mm; SH + 3.2 ± 1.8 mm). Although both groups increased (p < 0.01) the pennation angle of vastus lateralis (MIC + 2.90° ± 0.95°; SH + 1.90° ± 1.35°, p < 0.01), the change measured in MIC was higher (p = 0.045) than that observed in SH. Furthermore, only MIC enlarged (p < 0.01) the pennation angle of brachialis (MIC + 1.93 ± 1.51). Both groups improved (p < 0.05) bench press strength and power but only MIC enhanced (p < 0.01) vertical jump height. At post intervention, only MIC decreased (p < 0.05) DOMS at 12-h, 24-h, and 48-h after performing an exercise-induced muscle soreness protocol.
Conclusion
A 3-h daily use of microcurrent maximized muscular architectural changes and attenuated DOMS with no added significant benefits on body composition and performance.
Publisher
Springer Science and Business Media LLC
Subject
Physiology (medical),Public Health, Environmental and Occupational Health,Orthopedics and Sports Medicine,General Medicine,Public Health, Environmental and Occupational Health,Physiology
Reference43 articles.
1. Aagaard P, Andersen JL, Dyhre-Poulsen P et al (2001) A mechanism for increased contractile strength of human pennate muscle in response to strength training: changes in muscle architecture. J Physiol 534:613–623.
https://doi.org/10.1111/j.1469-7793.2001.t01-1-00613.x
2. Ahmed AF, Elgayed SSA, Ibrahim IM (2012) Polarity effect of microcurrent electrical stimulation on tendon healing: biomechanical and histopathological studies. J Adv Res 3:109–117.
https://doi.org/10.1016/j.jare.2011.05.004
3. Bijur P, Silver W, Gallagher E (2001) Reliability of the visual analog scale for measurement of acute pain. Acad Emerg Med 8:1153–11577.
https://doi.org/10.1111/j.1553-2712.2001.tb01132.x
4. Bradley M, O’Donnell P (2002) Atlas of musculoskeletal ultrasound anatomy. Greenwich Medical Media, London
5. Cohen J (1988) Statistical power analysis for the behavioral sciences, 2nd edn. Lawrence Erlbaum, Mahwah
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献