Low polyethylene creep and wear following mobile-bearing unicompartmental knee replacement

Author:

Ghosh Priyanka,Mohammad Hasan R.,Martin Benjamin,Campi Stefano,Murray David W.,Mellon Stephen J.ORCID

Abstract

Abstract Purpose The Oxford unicompartmental knee replacement (UKR) has a fully congruent mobile bearing to minimise wear. However, with younger higher demand patients, wear remains a concern. The aim of this study was to quantify the wear rate of Phase 3 Oxford UKR bearings over the course of 5 years and to identify the factors that influence it. Methods 40 medial Oxford UKRs recruited for a randomised study of cemented and cementless fixation were studied with Radiostereometric analysis (RSA) at 1 week, 3 months, 6 months, 1 year, 2 years, and 5 years post-operatively and bearing thickness was calculated. Penetration, defined as the change in thickness compared to the 1-week measurement, was determined. Creep (early penetration) and wear (late penetration at a constant rate) were calculated. The influence of demographic factors, Oxford Knee Score (OKS), Tegner score, fixation and bearing overhang (determined by RSA) on wear was analysed. Results After 6 months the penetration rate was constant, indicating that wear alone was occurring. The wear rate was 0.07 mm/year (SD 0.03). The creep was 0.06 mm with about 95% occurring during the first 3 months. There was no significant relationship between fixation (cemented/cementless), age, component size, OKS and Tegner score with wear rate. Increasing BMI was associated with decreasing wear (p = 0.042). 37/40 bearings overhung the tibia to some extent and 23/40 overhung the tibia medially. An increase in the area of overhang (p = 0.036), amount of medial overhang (p = 0.028) and distance between the bearing and tibial wall (p = 0.019) were associated with increased wear. Bearings that did not overhang (0.06 mm/year) had less wear (p = 0.025) than those that did (0.08 mm/year). There was no relationship (p = 0.6) between the femoral contact area and wear. Conclusion During the first three to six months after implantation, the bearing becomes 0.06 mm thinner due to creep. The combined wear rate of the upper and lower surfaces of the bearing is constant (0.07 mm/year). The wear is lower if the bearing does not overhang the tibia so surgeons should aim for the bearing to be close to the tibial wall. The orientation of the femoral component does not influence wear. Level of evidence Retrospective Study, Level III.

Funder

Zimmer Biomet

University of Oxford

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3