Low rate of substantial loss of reduction immediately after hardware removal following acromioclavicular joint stabilization using a suspensory fixation system

Author:

Rupp Marco-Christopher,Kadantsev Pavel M.,Siebenlist Sebastian,Hinz Maximilian,Feucht Matthias J.,Pogorzelski Jonas,Scheiderer Bastian,Imhoff Andreas B.ORCID,Muench Lukas N.,Berthold Daniel P.

Abstract

Abstract Purpose To evaluate immediate loss of reduction in patients undergoing hardware removal after arthroscopically assisted acromioclavicular (AC) joint stabilization using a high-tensile suture tape suspensory fixation system and to identify risk factors associated with immediate loss of reduction. Materials and methods Twenty-two consecutive patients with a mean age of 36.4 ± 12.6 years (19–56), who underwent hardware removal 18.2 ± 15.0 months following arthroscopically assisted stabilization surgery using a suspensory fixation system for AC joint injury between 01/2012 and 01/2021 were enrolled in this retrospective monocentric study. The coracoclavicular distance (CCD) as well as the clavicular dislocation/acromial thickness (D/A) ratio were measured on anterior–posterior radiographs prior to hardware removal and immediately postoperatively by two independent raters. Loss of reduction, defined as 10% increase in the CCD, was deemed substantial if the CCD increased 6 mm compared to preoperatively. Constitutional and surgical characteristics were assessed in a subgroup analysis to detect risk factors associated with loss of reduction. Results Postoperatively, the CCD significantly increased from 12.6 ± 3.7 mm (4.8–19.0) to 14.5 ± 3.3 mm (8.7–20.6 mm) (p < 0.001) while the D/A ratio increased from 0.4 ± 0.3 (− 0.4–0.9) to 0.6 ± 0.3 (1.1–0.1) (p = 0.034) compared to preoperatively. In 10 cases (45%), loss of reduction was identified, while a substantial loss of reduction (> 6 mm) was only observed in one patient (4.5%). A shorter time interval between index stabilization surgery and hardware removal significantly corresponded to immediate loss of reduction (11.0 ± 5.6 vs. 30.0 ± 20.8 months; p = 0.007), as hardware removal within one year following index stabilization was significantly associated with immediate loss of reduction (p = 0.027; relative risk 3.4; odds ratio 11.67). Conclusions Substantial loss of reduction after hardware removal of a high-tensile suture tape suspensory fixation system was rare, indicating that the postoperative result of AC stabilization is not categorically at risk when performing this procedure. Even though radiological assessment of the patients showed a statistically significant immediate superior clavicular displacement after this rarely required procedure, with an increased incidence in the first year following stabilization, this may not negatively influence the results of ACJ stabilization in a clinically relevant way. Level of evidence IV.

Funder

Technische Universität München

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3