Abstract
Abstract
Purpose
To compare the clinical outcome of arthroscopic capsulolabral repair for traumatic anterior shoulder instability with PEEK knotless and knotted biodegradable suture anchors.
Methods
Arthroscopic stabilization was performed in 78 patients with recurrent traumatic anterior shoulder instability. They were divided into 2 groups of 39 patients each, according to suture anchors used: knotless PEEK anchors in group 1, and biodegradable anchors in group 2. Exclusion criteria were: instability without dislocation, posterior or multidirectional instability, glenoid bone loss > 20%, off-track lesions, concomitant rotator cuff tears and previous surgery. The primary outcome was the Disabilities of the Arm, Shoulder and Hand (DASH) self-administered questionnaire. Secondary outcomes were: Work-DASH, Sport-DASH, Rowe score, recurrent instability and subsequent surgery. The following independent variables were considered: age, gender, dominance, generalized ligamentous hyperlaxity, duration of symptoms, age at first dislocation, number of dislocations, type of work, type of sport, sports activity level, capsule-labral injury pattern, SLAP lesion and number of anchors. Differences between groups for numerical variables were analyzed by use of the Student’s t-test or Mann–Whitney U-test. Fisher’s exact test was used for analysis of categorical variables. Significance was set at p < 0.05.
Results
Seven patients (9%) were lost at follow-up, 5 from group 1 and 2 from group 2. Follow-up ranged from 36 to 60 months (median: 44; IQR: 13). Comparison between groups did not show significant differences for each independent variable considered. No differences could be found either for DASH (n.s.) or Rowe (p = n.s.) scores between the two groups. Overall recurrence rate was 7%. Three re-dislocations were reported in group 1 and two in group 2 (n.s.). Only one patient in each group underwent re-operation.
Conclusions
The study showed no significant differences in clinical outcomes after arthroscopic treatment of traumatic anterior shoulder instability using PEEK knotless or biodegradable knotted anchors at mid-term follow-up.
Level of evidence
I.
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Surgery
Reference33 articles.
1. Barber FA, Coons DA, Ruiz-Suarez M (2008) Cyclic load testing and ultimate failure strength of biodegradable glenoid anchors. Arthroscopy 24:224–228
2. Beighton P, Horan F (1969) Orthopaedic aspects of the Ehlers-Danlos syndrome. J Bone Joint Surg Br 51:444–453
3. Bents EJ, Brady PC, Adams CR, Tokish JM, Higgins LD, Denard PJ (2017) Patient-reported outcomes of knotted and knotless glenohumeral labral repairs are equivalent. Am J Orthop Belle Mead NJ 46:279–283
4. Brown L, Rothermel S, Joshi R, Dhawan A (2017) Recurrent instability after arthroscopic Bankart reconstruction: a systematic review of surgical technical factors. Arthroscopy 33:2081–2092
5. Cho NS, Lubis AMT, Ha JH, Rhee YG (2006) Clinical results of arthroscopic Bankart repair with knot-tying and knotless suture anchors. Arthroscopy 22:1276–1282
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献