Organ-specific accuracy of [18F]FDG-PET/CT in identifying immune-related adverse events in patients with high-risk melanoma treated with adjuvant immune checkpoint inhibitor

Author:

Gideonse Birte Molvik,Birkeland Magnus,Vilstrup Mie Holm,Grupe Peter,Naghavi-Behzad MohammadORCID,Ruhlmann Christina H.,Gerke Oke,Hildebrandt Malene Grubbe

Abstract

Abstract Purpose This study aimed to determine the organ-specific accuracy of [18F]FDG-PET/CT in identifying immune-related adverse events (irAEs) in patients with high-risk (stage III/IV) surgically resected melanoma treated with an adjuvant immune checkpoint inhibitor (ICI) and determine the incidence of irAEs within the first year after starting treatment. Materials and methods This registry-based study included individuals who had undergone surgical removal of melanoma and were undergoing adjuvant ICI treatment (either nivolumab or pembrolizumab). The study specifically enrolled patients who had undergone both a baseline and at least one subsequent follow-up [18F]FDG-PET/CT scan. Follow-up scans were performed every third month in the first year after surgery to screen for disease recurrence. We retrospectively compared the follow-up scans with baseline scans to identify irAEs. Clinical information on irAEs was obtained from medical records and served as a reference standard for determining the accuracy of [18F]FDG-PET/CT. Results A total of 123 patients with 363 [18F]FDG-PET/CT scans were included, and 65 patients (52.8%) developed irAEs. In decreasing order, the organ-specific incidences of irAEs were: skin 26/65 (40%), muscle and joints 21/65 (32.3%), intestines 13/65 (20%), thyroid gland 12/65 (18.5%), lungs 4/65 (6.2%), and heart 2/65 (3.1%). The sensitivities and specificities of [18F]FDG-PET/CT for diagnosing irAEs were: skin 19% (95% CI: 7–39%) and 95% (88–98%), muscles and joints 71% (48–89%) and 83% (75–90%), intestines 100% (75–100%) and 85% (77–91%); thyroid gland 92% (62–99%) and 95% (89–98%), lungs 75% (19–99%) and 90% (83–95%), and heart 50% (13–99%) and 97% (92–99%), respectively. Conclusion [18F]FDG-PET/CT generally had moderate to high sensitivities (except for skin and heart) and specificities in diagnosing irAEs in patients receiving adjuvant ICI; this could be suggested to be systematically assessed and reported in scan reports.

Funder

Odense Universitetshospital

Klinisk Institut, Syddansk Universitet

Odense University Hospital

Publisher

Springer Science and Business Media LLC

Reference53 articles.

1. Onitilo AA, Wittig JA. Principles of immunotherapy in melanoma. Surg Clin North Am. 2020;100:161–73.

2. Sandru A, Voinea S, Panaitescu E, Blidaru A. Survival rates of patients with metastatic malignant melanoma. J Med Life. 2014;7:572–6.

3. Weber J, Mandala M, Del Vecchio M, et al. Adjuvant nivolumab versus ipilimumab in resected stage III or IV melanoma. N Engl J Med. 2017;377:1824–35.

4. Larkin J, Chiarion-Sileni V, Gonzalez R, et al. Combined nivolumab and ipilimumab or monotherapy in untreated melanoma. N Engl J Med. 2015;373:23–34.

5. Sabag N, Yakobson A, Silberstein E. Recent changes and innovations in melanoma treatment: a review. Isr Med Assoc J. 2020;11:704–10.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3