Abstract
AbstractSystems capable of disinfecting air and surfaces could reduce the risk of infectious diseases transmission. Aim: to evaluate the effectiveness of near-UV LED ceiling lamps, with a wavelength of 405 nm, in improving environmental hygiene. Between November and December 2020, we conducted an experimental study having a pre-post design in a kindergarten room in Siena where 4 ceiling lamps with 405 nm LED technology were installed. Twice per day, sampling was performed before (T0) and after treatment with near-UV (T1). We used between 8 and 12 pairs of contact plates to sample at various random spots each day. Air samplings were also performed. The plates were incubated at 22 and 36 °C. Significance was set at 95% (p < 0.05). The mean level of Colony Forming Unit (CFU) at T(0) was 249 (95% CI 193.1 – 305.0) at 36 °C and 535.2 (374.3 – 696.1) at 22 °C. The reduction was significant at T(1): by 65% at 36 °C and, 72% at 22 °C. Also, for air contamination: 95.3% (98.4—92.3). A dose threshold of about 5 J/cm2 was identified to have an 80% CFU abatement and remains nearly constant. The advantage of being able to use this technology in the presence of people is very important in the context of controlling environmental contamination.
Graphical abstract
Funder
Ugolini & C. SRL
Università degli Studi di Siena
Publisher
Springer Science and Business Media LLC
Subject
Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health,Pollution,Waste Management and Disposal,Water Science and Technology,Applied Microbiology and Biotechnology,Environmental Engineering
Reference31 articles.
1. Guidelines for non-pharmaceutical interventions to reduce the impact of COVID-19 in the EU/EEA and the UK. 24 September 2020. ECDC: Stockholm; 2020.
2. Cauchemez S, Bhattarai A, Marchbanks TL, Fagan RP, Ostroff S, Ferguson NM, Swerdlow D, The Pennsylvania H1N1 working group, Sodha SV, Moll ME, et al. Role of social networks in shaping disease transmission during a community outbreak of 2009 H1N1 pandemic influenza. Proc Natl Acad Sci. 2011;108:2825–2830. https://doi.org/10.1073/pnas.1008895108.
3. Read JM, Zimmer S, Vukotich C, Schweizer ML, Galloway D, Lingle C, Yearwood G, Calderone P, Noble E, Quadelacy T, et al. Influenza and other respiratory viral infections associated with absence from school among schoolchildren in Pittsburgh, Pennsylvania, USA: a cohort study. BMC Infect Dis. 2021;21:291. https://doi.org/10.1186/s12879-021-05922-1.
4. Chao DL, Elizabeth Halloran M, Longini IM Jr. School opening dates predict pandemic influenza A(H1N1) outbreaks in the United States. J Infect Dis. 2010;202:877–80. https://doi.org/10.1086/655810.
5. COVID-19 in children and the role of school settings in transmission - Second update. Available online: https://www.ecdc.europa.eu/en/publications-data/children-and-school-settings-covid-19-transmission. Accessed on 18 Oct 2021.
Cited by
2 articles.