Abstract
Abstract
Background
An accurate, rapid estimate of glomerular filtration rate (GFR) in kidney transplant patients affords early detection of transplant deterioration and timely intervention. This study compared the performance of serum creatinine (Cr) and cystatin C (CysC)-based GFR equations to measured GFR (mGFR) using iohexol among pediatric kidney transplant recipients.
Methods
CysC, Cr, and mGFR were obtained from 45 kidney transplant patients, 1–18 years old. Cr- and CysC-estimated GFR (eGFR) was compared against mGFR using the Cr-based (Bedside Schwartz, U25-Cr), CysC-based (Gentian CysC, CAPA, U25-CysC), and Cr-CysC combination (CKiD Cr-CysC, U25 Cr-CysC) equations in terms of bias, precision, and accuracy. Bland–Altman plots assessed the agreement between eGFR and mGFR. Secondary analyses evaluated the formulas in patients with biopsy-proven histological changes, and K/DOQI CKD staging.
Results
Bias was small with Gentian CysC (0.1 ml/min/1.73 m2); 88.9% and 37.8% of U25-CysC estimations were within 30% and 10% of mGFR, respectively. In subjects with histological changes on biopsy, Gentian CysC had a small bias and U25-CysC were more accurate—both with 83.3% of and 41.7% of estimates within 30% and 10% mGFR, respectively. Precision was better with U25-CysC, CKiD Cr-CysC, and U25 Cr-CysC. Bland–Altman plots showed the Bedside Schwartz, Gentian CysC, CAPA, and U25-CysC tend to overestimate GFR when > 100 ml/min/1.72 m2. CAPA misclassified CKD stage the least (whole cohort 24.4%, histological changes on biopsy 33.3%).
Conclusions
In this small cohort, CysC-based equations with or without Cr may have better bias, precision, and accuracy in predicting GFR.
Graphical abstract
Funder
Gentian Diagnostics
Cedars-Sinai Medical Center
Publisher
Springer Science and Business Media LLC
Reference41 articles.
1. National Kidney Foundation (2002) K/DOQI clinical practice guidelines for chronic kidney disease: evaluation, classification, and stratification. Am J Kidney Dis 39:S1–S266
2. Arant BS Jr, Edelmann CM Jr, Spitzer A (1972) The congruence of creatinine and inulin clearances in children: use of the Technicon AutoAnalyzer. J Pediatr 81:559–561
3. Gaspari F, Perico N, Ruggenenti P, Mosconi L, Amuchastegui CS, Guerini E et al (1995) Plasma clearance of nonradioactive iohexol as a measure of glomerular filtration rate. J Am Soc Nephrol 6:257–263
4. Olsson B, Aulie A, Sveen K, Andrew E (1983) Human pharmacokinetics of iohexol. A new nonionic contrast medium. Invest Radiol 18:177–182
5. Nilsson-Ehle P (2001) Iohexol clearance for the determination of glomerular filtration rate: 15 years’ experience in clinical practice. EJIFCC 13:48–52