Unnecessary radiation exposure during diagnostic radiography in infants in a neonatal intensive care unit: a retrospective cohort study

Author:

Su Yu-Tsun,Chen Yu-Shen,Yeh Lee-Ren,Chen Shu-Wen,Tsai Yu-Cheng,Wu Chien-Yi,Yang Yung-Ning,Tey Shu-Leei,Lin Chyi-Her

Abstract

AbstractUnnecessary radiation exposure (URE) during radiographic examination is an issue among infants in neonatal intensive care units (NICUs). The causes of URE have not been fully explored. This study investigated the incidence and identified the causes of URE in infants during diagnostic radiography in a NICU. This was a retrospective cohort study. We retrieved and analysed requests and radiographs taken at a tertiary NICU between September and November 2018. URE was defined as the rate of discordance between requests and images taken (DisBRI) and unnecessary radiation exposure in irrelevant regions (UREIR) during radiography. We compared the rates of URE between very low-birth-weight (VLBW, birth weight < 1500 g) infants and non-VLBW infants. A total of 306 radiographs from 88 infants were taken. The means ± standard deviations (SDs) of gestational age and birth weight were 35.7 ± 3.6 weeks and 2471 ± 816 g, respectively. Each infant underwent an average of 3.5 radiographs. The DisBRI rate was 1.3% and was mostly related to poor adherence to requests. The UREIR rates in thoraco-abdominal babygrams were 89.6% for the head, 14.8% for the elbows and 18.4% for the knee and were mainly related to improper positioning of and collimation in infants while performing radiography. The UREIR rates for the head, knee and ankle were higher in VLBW infants than in non-VLBW infants (94.6% vs. 85.6%, 27.0% vs. 11.5% and 5.4% vs. 0.7%, respectively, p < 0.05).Conclusions: URE during diagnostic radiography is common in sick infants and is mainly related to improper positioning and collimation during examinations. Adherence to protocols when performing radiographic examination or using ultrasonography may be a solution to reduce URE in infants in NICUs. What is Known:• The risk of unnecessary radiation exposure (URE) during radiography has been a common and important issue in sick infants in neonatal intensive care units (NICUs).• The new point-of-care ultrasound (POCUS) technique decreases the need for chest films and prevents radiation exposure in neonates. What is New:• In the NICU, URE is still a common issue in critically ill infants during radiographic examinations. The causes of URE during diagnostic radiography are mainly due to improper positioning and collimation during examinations.• The incidence of URE in irrelevant regions is higher in very low-birth-weight (VLBW) infants than in non-VLBW infants.

Funder

E-Da Hospital

E-Da Hospital, Taiwan, and I-Shou University, Taiwan

Publisher

Springer Science and Business Media LLC

Subject

Pediatrics, Perinatology and Child Health

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3