Author:
Pretorius Erna,van Zyl Paulina,Joubert Gina
Abstract
Abstract
Background
Monitoring free valproate concentrations, as with other highly protein-bound anticonvulsants, is essential in clinical situations where protein binding may be disrupted. Conversion of measured total concentrations to approximate free concentrations offers a cost-effective alternative. This study evaluated the relationship between total and free valproate concentrations for discordance and the impact of key determinants. A novel formula was devised that incorporates significant variables.
Methods
A multicentre, cross-sectional observational analytical study included 101 subjects 18 years and older using valproate for 6 months or longer. Participants were recruited from private and public sector healthcare settings from primary to tertiary level in, South Africa, during 2017–2019.
Results
Free valproate concentrations could be measured for 84 subjects. Discordance for concomitant total and free valproate concentrations was 79.1%. Among 19 participants with elevated free concentrations, 15 (78.9%) had total valproate concentrations within the recommended reference range. Calculations based on the study-derived formula were more accurate in predicting free valproate concentration than previously proposed methods.
Conclusion
This study proposes that the novel formula for calculating free valproate enables more accurate prediction.
Funder
University of the Free State
Publisher
Springer Science and Business Media LLC