(In)comparability of Carotid Artery Stent Characteristics: A Systematic Review on Assessment and Comparison with Manufacturer Data

Author:

de Vries Evelien E.,Kök Mert,Hoving Astrid M.,Slump Cornelis H.,Toorop Raechel J.,de Borst Gert J.

Abstract

Abstract Purpose Carotid stent (CS) characteristics, such as radial force, scaffolding and flexibility, are continuously modified by stent manufacturers aiming to improve stent performance. Since manufacturers’ definitions and assessment methods are not disclosed, it is unknown how characteristics of different CSs relate to each other or to published literature. We examined in vitro methodological techniques used to measure CS characteristics and assessed comparability between published papers and outcomes as provided by the manufacturers. Methods A systematic review was conducted in MEDLINE, Embase, Cochrane, and Scopus databases. Studies reporting on in vitro investigations of predefined characteristics of CS used in current everyday clinical practice were included. The predefined characteristics were radial force, scaffolding, flexibility, foreshortening, side-branch preservation and visibility. Eight manufacturers of 10 currently used CS were contacted and data on the predefined device characteristics was requested. Results 12 published articles were included and six stent manufacturers provided data on six stents (two refused to share data). Used methodologies to measure stent characteristics in published literature and manufacturer data varied greatly for all included characteristics except foreshortening. The number of different units of measurement to express outcomes ranged from two for foreshortening to six for radial force. Conclusion A variety of methodologies and outcome measures is used to quantify CS characteristics, which hampers comparisons between published studies and manufacturer data. Future studies are encouraged to synchronize methodologies and outcome measures. Manufacturers are encouraged up to increase transparency of applied testing methodologies and outcomes.

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3