Influence of Interventionists’ Experience on Radiation Exposure of Patients Who Underwent Prostate Artery Embolization: 4-Year Results from a Retrospective, Single-Center Study

Author:

Kriechenbauer Bernadette Maria Theresia,Franiel Tobias,Bürckenmeyer Florian,Aschenbach René,Diamantis Ioannis,Malouhi Amer,Steiniger Beatrice,Teichgräber Ulf

Abstract

Abstract Purpose To assess radiation exposure in men undergoing prostate artery embolization (PAE) for the treatment for symptomatic, benign prostatic hyperplasia depending on growing experience of interventional radiologists over a 4-year period. Methods A total of 250 consecutive patients underwent PAE at a single center. Data on radiation exposure [dose area product (DAP), effective dose (ED), entrance skin dose (ESD), and fluoroscopy time (FT)] were retrospectively evaluated. Primary outcomes of interest were patient radiation exposure in five consecutive groups of 50 patients each and Pearson correlation with the number of patients treated. Results Median DAP, ED, and ESD during prostate artery embolization were significantly higher in the first compared to the second 50 patients (56 298 µGym2 vs. 24 709 µGym2, p < 0.001, 146.4 mSv vs. 64.2 mSv, p < 0.001, and 5.1 Gy vs. 2.4 Gy, p < 0.001, respectively). The following consecutive groups did not differ significantly from the respective preceding group in terms of DAP, ED, and ESD. Number of digital subtraction angiography series, FT, and procedure time decreased with increasing operator experience (Pearson’s r = − 0.240, p < 0.001, r = − 0.269, p < 0.001, and r = − 0.504, p < 0.001, respectively). Bilateral prostate artery embolization was associated with less ESD and shorter FT than unilateral embolization (median 2.5 vs. 3.5 Gy, p = 0.02, and 26 min vs. 42 min, p < 0.001, respectively). Conclusion Exposure to radiation in men who underwent PAE decreased with growing operator experience and decreasing complexity of procedures.

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3